CellCom‑LTE‑V Programming and Installation Guide
Digital
Monitoring
Products
35
APPENDIX
This section provides additional zone and system information.
False Alarm Reduction
System Recently Armed report
The system recently armed report (S78) is sent when a burglary zone goes into alarm within two minutes of the
system being armed.
Diagnostics Function
The communicator contains a diagnostics function that allows you to test the integrity of the cellular communication
and cellular signal. You may also check panel settings with the diagnostics function. To use diagnostics, reset the
communicator and enter the diagnostics code 2313 (DIAG).
Cellular Status
This option tests the individual components of cellular communication. Entry into the CELL STATUS menu will prompt
each component of the cellular communication to be tested. The test will proceed until the first component failure or
until all components have been tested with positive results. The test screen will display after each component and will
be displayed for two seconds or until CMD has been pressed.
Cellular Signal Strength (CELL SIGNAL)
This option provides a way to test the cellular signal strength of the nearest tower for the
cellular carrier. Press any select area to display cell signal strength. The X’s represent the
numerical value of the cell signal strength in ‑dBm. The
▐
’s represent the signal strength
0‑7.
Panel Settings
Press a top row key to access the MAC address, serial number, model, and firmware version.
Serial Number
This number is the communicator serial number. Reference this number for communicator date‑of‑manufacture and
hardware version. Press any select area to display the serial number.
Model Number
This menu option displays the model number of the communicator.
Firmware Version
This menu option displays the firmware version number of the communicator and date it was released.
Z‑Wave Test Option (CellComZ‑LTE‑V only)
This feature allows the installer to test communicator communication with Z‑Wave devices.
A successful test indicates a response from a device. Press any select area to view the
Z‑Wave device list.
Press CMD to advance through each Z‑Wave device and press any select area to begin the
test on the device displayed.
The name of the device displays above the device number. The current number of
successful communications followed by the total number of attempts displays to the right
of the device number. The test stops after 99 attempts.
Press CMD to view the final number of successful communications.
Contact ID Recvd
This displays DTMF digits dialed from the burglary control panel.
Exiting the Diagnostics program
Press CMD until STOP displays. Press any select area. The keypad returns to the status list display.
‑XX dBm
SIGNAL:
▐▐▐▐▐▐▐
TEST ZWAVE
DEVICE LIST:
HALLWAY LIGHT
HALLWAY LIGHT
LIGHT 02 0/0
HALLWAY LIGHT
99/99
SUCCESSFUL