Digital
Monitoring
Products
CellCom‑LTE‑V Programming and Installation Guide
18
COMMUNICATION
COMMUNICATION
This option allows you to configure the communication settings for the communicator.
ACCOUNT NUMBER
Enter the account num ber sent to the receiver. The range is 1‑65535. For account numbers
of four digits or less, do not enter leading zeros.
TRANSMISSION DELAY
Enter the number of seconds the communicator waits before sending burglary alarm
reports to the receiver. The range is 15‑45 seconds. The default is 0. Enter 0 to disable this
function.
COMMUNICATION TYPE
The communicator uses CELL communication to DMP Model SCS‑1R or SCS‑VR Receivers.
TEST TIME
Enter the time of day the communicator should send the test report to the SCS‑1R or
SCS‑VR receivers. Use entries between 12:00 to 11:59 and then choose AM or PM. To enable
daily tests from the host panel, leave the time blank and enable test reports for receiver 1
and/or for receiver 2. See Test Report.
TEST DAYS
If you entered a test time, you can enter how often the panel test report is sent to the
receiver. The range is 1 to 60 and the default is 1. Enter 0 to disable the test report.
CELL CHECK‑IN
Check‑in reports are a method of supervising the panel for communication with
the receiver. Enter the number of minutes between check‑in reports. The range is
3‑240 minutes. The default is 0. Enter 0 to disable check‑in minutes.
Note: Additional cell charges may apply if this option is used.
FAIL TIME
Fail time allows the SCS‑1R or SCS‑VR receivers to miss a defined number of check‑ins
before logging that the panel is missing. For example, if cell check‑in is 20 minutes and fail
time is 30 minutes, the receiver only indicates a Panel Not Responding after 30 minutes.
The fail time must be equal to or greater than the cell check‑in minutes. If cell check‑in
is 20 minutes, the fail time must be 20 minutes or more. The range is 3‑240 minutes. The
default is 0.
RECEIVER 1 PROGRAMMING
This option allows you to set the options for the first receiver the communicator attempts
to contact when sending reports from the host panel and/or communicator. The
communicator supports communication up to two receivers.
ALARM REPORTS
Choose YES to enable Abort, Alarm, Alarm Restoral, Alarm Bell Silenced, Ambush, Exit
Error, and System Recently Armed reports to be sent to this receiver. The default is YES.
Choose NO to disable sending these reports to the receiver.
SUPERVISORY/TROUBLE REPORTS
Choose YES to enable Supervisory, Trouble, Trouble Restoral, Force Armed, and Fault
reports to be sent to this receiver. The default is YES.
Choose NO to disable sending these reports to the receiver.
OPENING/CLOSING AND USER REPORTS
Choose YES to enable Opening/Closing, Schedule and Code Changes, and Bypass reports
by user to be sent to this receiver. The default is YES.
Choose NO to disable sending these reports to the receiver.
COMMUNICATION
ACCOUNT NO:
XMIT DELAY:
0
COMM TYPE: CELL
TEST TIME
00:00 AM
CELL TST DAYS:
1
CHECKIN:
0
FAIL TIME:
0
RECEIVER 1 PROG
ALARM NO
YES
SPV/TRBL NO
YES
O/C USER NO
YES