CellCom‑LTE‑V Programming and Installation Guide
Digital
Monitoring
Products
13
REMOTE ARMING AND DISARMING
Virtual Keypad App
Using a smartphone with the DMP Virtual Keypad App or a computer with VirtualKeypad.com, you can connect to the
communicator to arm areas, turn outputs on and off, and add, edit, or remove users. See Figure 10.
Using Outputs to Arm and Disarm
A burglary control panel zone may be programmed as an arming zone and connected to output O1 or O2. See
Figure 11. Program the output number in armed output or remote arming output in output options when programming
the communicator. See Armed Output or Remote Arming Output. The communicator output connections can be used
with any of the applications listed in this guide. See Applications.
Figure 10: Virtual Keypad Application
Figure 11: Communicator to Burglary Control Panel Zones
Use 18-22 AWG for
Power Supply connection
O1
O2
12VDC Aux. Output
+
-
Control Panel
MODEL CellCom-LTE-V
PROG
+12
G
Z1
Z2
Z4-
Z4+
G
Z3
R
T
O2
O1
R
B
GND
Zone 1
Zone 2
Control Panel EOL resistor