Digital Monitoring Products, Inc | 9000 Series Installation and Programming Guide
13
Default Keypad Message
Enter a custom message of up to 16 characters to appear at
the top of the keypad display. Press any select key, enter a new
message, and press
CMD
.
Arm Panic Keys
Use this option to configure the select keys as two-button
panic keys. To enable or disable a panic option, press
the select key under the desired name:
PN
(panic),
EM
(emergency), and
FI
(fire). Press the select key again to disable
the panic option. Once the panic option is enabled, an asterisk
displays next to the selected option(s).
ALL? NO YES (9063 only)
Select the number of seconds (1-9) the keypad should
wait when an area system displays
ALL? NO YES
during
arming/disarming or a HOME/SLEEP/AWAY system waits
during arming only. If
NO
or
YES
, or
HOME
,
SLEEP
, or
AWAY
is not manually selected before the delay expires, the keypad
automatically selects
YES
or
AWAY
. Select zero (0) to disable
this feature. The delay also occurs when any credential is
presented for arming the Home/Sleep/Away system. Default
is
2
.
Enable Tamper?
Select
YES
to enable wall tamper protection. Default is
NO
.
DEFAULT KPD MSG:
ARM PANIC KEYS:
*PN *EM *FI
ALL?: NO
YES
DELAY:
2
ENABLE TAMPER?
NO YES