Elevator car Positioning System and Stopping Accuracy
ELGO LIMAX 33 CP Absolute Encoder Counting System
N.
Fault
Type
Description
Remedy
60 Fault ELGO
ELGO Fault.
Cod 4: Pre-triggered Stopping system
Top
Cod 5: Pre-triggered Stopping system
Bottom
Cod 8: Normal mode overspeed (pre
tripping)
Cod 9: Normal mode overspeed (final
tripping)
Cod 11: Inspection mode overspeed (final
tripping)
Cod 13: Teach mode overspeed (final
tripping)
Cod 14: Normal mode overspeed
(leveling)
Cod 15: Normal mode overspeed (re-
leveling)
Cod 24: Unintended car movement
Cod 100: ELGO not in operative mode
Cod 102: ELGO’s Input EN81-21 in
Manual Teach mode
Cod 103: ELGO’s eSGC_POW missing in
Manual Teach mode
Cod 104: Restarting error in Manual
Teach mode
Cod 200: Communication time out
Cod 255: Magnetic Band missing
Check ELGO configuration data.
Check ELGO wiring
Make a Fault reset to remove the
fault.
This symbol means a blocking fault: switch off main power and then switch it on again to put the lift back in service.
The absolute encoder allows you to replace all the safety contacts inside the lift shaft. The position of the cabin is
detected thanks to a magnetic strip.
Features:
• Absolute position detection and safety functions:
ELGO LIMAX 33 CP Absolute Encoder Counting System