“Special Features” Menu
----->>>>>
----->>>>>
OR
----->>>>>
----->>>>>
Floor 0 - 12:30:56
< Special Features >
Table of Parameters:
Parameter
Description
Navigation
Values
Default
Value
Reset in
Direction of travel during reset procedure
◄► (Selection)
2 s <-> 30
s
10 s
Travelling
limits in
inspection
Valid only for FAI/FAS positioning system.
Settings for the travelling limits during inspection
mode.
If travelling is programmed beyond the limits, the
controller does not allow any movement beyond
top/bottom floors.
◄► (Selection)
Permanent;
Blinking at
floors
Permanent
Fire-fighters
(Refer to Annex XI - Fire operation programming
procedure )
Type of fire-fighter operations (if present) and
relevant parameters (fire service access level and
side, POM and CPOM key contact type); choice
of relevant applicable norm:
-) Norm NF P82-207 (France);
-) EN 81-72 (a): no car FF key switch;
-) EN 81-72 (b): with car FF key switch;
◄► (Select field)
▲▼ (Change value)
Not
present;
NF P82-
207;
EN 81-72
(a);
EN 81-72
(b)
Not
present
Fire
detection
Parameter for fire detection at floors. When a fire
is detected:
- if the lift is at a different floor than the one where
fire was detected, all registered calls from/to this
floor are cancelled;
- if the lift is at the floor where fire was detected,
the controller blocks door opening, closes doors
(if open upon fire detection) and sends the car to
a safe floor
◄► (Selection)
No;
Yes
No
Stop button
registration
The system registers the out of service mode
(pressure of STOP button).
It is also possible to set the delay to avoid
simultaneous movement in installations powered
with a generator.
◄► (Selection)
No;
Yes
No
Table of Parameters