background image

 
 

USER GUIDE 

 

The "ULTIMATE" REMOTE CONTROL AND 

AUTOMATION INTERFACE MODULE 

 

FOR THE SAGE-ENDEC MODEL SE1822 and 3644 Digital E.A.S. 

ENCODER/DECODER 

 

 

Software Version 1.4  

Rev. 2 

 

 

 

 

 

 

 

DM Engineering 
2174 Chandler St.  
Camarillo, CA 91345-4611  
805-987-7881 800-249-0487 
www.DMEngineering.com 

Summary of Contents for 3644

Page 1: ...OL AND AUTOMATION INTERFACE MODULE FOR THE SAGE ENDEC MODEL SE1822 and 3644 Digital E A S ENCODER DECODER Software Version 1 4 Rev 2 DM Engineering 2174 Chandler St Camarillo CA 91345 4611 805 987 7881 800 249 0487 www DMEngineering com 1 ...

Page 2: ...The Ultimate EAS Remote Control is a self contained microprocessor based device that interfaces with the Ultimate Interface module via a Category 5e cable of up to 50 in length RFI protection is included in the design to assure proper operation in both AM and FM RF environments The unit talks to the Sage Endec 1822 or Digital 3644 Encoder Decoder by means of a proprietary code and connects to the ...

Page 3: ...Endec 7 AUDIO GAIN This control adjusts the audio output level for both the internal speaker and earphones for the Preview Audio function It is provided with an off position to disable the internal audio amplifier if desired It is important to note that the RLS PEND KILL PEND and REVIEW AUDIO functions are only enabled when there is a pending alert active on the Sage Endec This prevents commands b...

Page 4: ...Output of the Sage Endec Please note that all audio alert tones digital signals and alert audio are present at this jack It may be used for a line input to a studio control board for alert playback using either the RLS PEND for the entire alert or the PREVIEW AUDIO audio portion only 4 LCD Contrast Control User screwdriver adjustable LCD contrast control This may be adjusted to accommodate the use...

Page 5: ...e DEC ACT OUTPUT relay function Installation The following menu Items and jumper connections must be set on the Sage Endec prior to connection of the Ultimate system It is advisable to remove power from the Endec prior to this installation to avoid accidental shorting within the Endec or initiation of a test Prevent damage to the Ultimate system by avoiding ground loops between the Ultimate interf...

Page 6: ... 4 5 or 6 on the rear of the Endec Secure the Module to the Endec using the captive screws provided as a part of the Module You may have to configure the selected port to 9600 baud as the default settings for all ports is 1200 baud Configure the selected port using menu devices port baud 3 The DB9 pigtail may be connected to any remaining available port other than COM 3 You may have to configure t...

Page 7: ...e the menu change password command on the Endec You will need the administrator s password to do this change and if it is not available consult section 14 3 of the SE1822 Endec User Guide or section 12 11 in the 3644 Digital Endec User Guide 11 Assure that the Decoder Active or Dec Rly relay is set to either the default Pending or to the Pending Done preferred relay program Go to menu relay and sc...

Page 8: ...Preview Audio button is pressed This is a timed and self muting function and turns off 5 seconds after the audio has ended Warranty Information The Ultimate Remote Control and Automation Interface Module are warranted for a period of one year from the date of purchase This warranty covers materials and workmanship only Any misapplication physical or electrical damage from outside sources or by the...

Page 9: ...ors supplied DB9 interface module with DB9 pigtail and Endec Automation control interface screw terminal connections Sage Endec Interface Serial RS 232 2 Endec ports required Power External power supply supplied Input 120VAC 50 60Hz Output 9VDC 350ma Power Cord Length approx 6 ft total Mounting Desktop Operating temperature 32 to 120F Humidity 0 to 95 non condensing Shipping Weight 4 lbs approxima...