have to configure the port to 9600 baud as the default setting is 1200 
baud.  Configure the ports using 

menu.devices.port.baud

.  Select another 

available COM port for LED sign operation by selecting; 

menu,devices.port.device.type.LED sign 

and connect the DB9 pigtail to 

this port.  If the COM 3 port is selected, you may have to configure the 
port to 9600 baud as the default setting is 1200 baud.  Configure the ports 
using 

menu.devices.port.baud

.. 

 
3644 Digital: 

1.  To enable the required DC voltage to pin 9 of the COM ports, remove the 

top cover of the Endec by removing the six retaining screws and slide the 
cover plate toward the rear of the Endec.  Locate “JP1” on the main green 
PCB covering the bottom of the case.  “JP1” is located towards the rear 
left corner of the PCB.  Do not confuse this “JP1” with the JP1 on the red 
daughter card.  You will find that the jumper is placed on only one of the 
pins by factory default.  Remove the jumper and place it on both pins of 
“JP1” and replace the cover.  Refer to section 13.2 of your Endec 3644 
Digital User Guide and Reference Manual. 

 
2.  The Interface Module may be connected to COM 3, 4, 5, or 6 on the rear 

of the Endec.  Secure the Module to the Endec using the captive screws 
provided as a part of the Module.  You may have to configure the selected 
port to 9600 baud as the default settings for all ports is 1200 baud.  
Configure the selected port using 

menu.devices.port.baud

 
3.  The DB9 pigtail may be connected to any remaining available port other 

than COM 3.  You may have to configure the selected port to 9600 baud 
as the default settings for all ports is 1200 baud.  Configure the selected 
port using 

menu.devices.port.baud

 

General: 

 

1.  Attach the supplied twisted wire pair to the “Decoder Active” or “Dec Rly” 

terminals on the rear of the Sage-Endec. Polarity is not important.  

 

 

2.  Attach the shielded wire to the “Speaker Line Out” and the closest “Audio 

Common” or “GND” terminals. The shield goes to the “Audio Common” or 
“GND” terminal.  

 

 

3.  Connect the twisted pair of wires from the Endec “Decoder Active” or “Dec 

Rly” terminals to the DEC ACT INPUT on the Interface Module. Polarity 
does not matter.  

 

 

4.  Connect the shielded conductor from the Endec “Speaker Line Out” and 

“Audio Common” or “GND” terminals to the AUDIO and COMMON 
connectors on the Interface Module. Shield goes to COMMON.  

 

 

 

5.  Connect any auxiliary control wiring you desire to the RWT, RLS PEND 

inputs, Decoder Active Output and EOM output terminals. The RWT and 

Summary of Contents for 3644

Page 1: ...OL AND AUTOMATION INTERFACE MODULE FOR THE SAGE ENDEC MODEL SE1822 and 3644 Digital E A S ENCODER DECODER Software Version 1 4 Rev 2 DM Engineering 2174 Chandler St Camarillo CA 91345 4611 805 987 7881 800 249 0487 www DMEngineering com 1 ...

Page 2: ...The Ultimate EAS Remote Control is a self contained microprocessor based device that interfaces with the Ultimate Interface module via a Category 5e cable of up to 50 in length RFI protection is included in the design to assure proper operation in both AM and FM RF environments The unit talks to the Sage Endec 1822 or Digital 3644 Encoder Decoder by means of a proprietary code and connects to the ...

Page 3: ...Endec 7 AUDIO GAIN This control adjusts the audio output level for both the internal speaker and earphones for the Preview Audio function It is provided with an off position to disable the internal audio amplifier if desired It is important to note that the RLS PEND KILL PEND and REVIEW AUDIO functions are only enabled when there is a pending alert active on the Sage Endec This prevents commands b...

Page 4: ...Output of the Sage Endec Please note that all audio alert tones digital signals and alert audio are present at this jack It may be used for a line input to a studio control board for alert playback using either the RLS PEND for the entire alert or the PREVIEW AUDIO audio portion only 4 LCD Contrast Control User screwdriver adjustable LCD contrast control This may be adjusted to accommodate the use...

Page 5: ...e DEC ACT OUTPUT relay function Installation The following menu Items and jumper connections must be set on the Sage Endec prior to connection of the Ultimate system It is advisable to remove power from the Endec prior to this installation to avoid accidental shorting within the Endec or initiation of a test Prevent damage to the Ultimate system by avoiding ground loops between the Ultimate interf...

Page 6: ... 4 5 or 6 on the rear of the Endec Secure the Module to the Endec using the captive screws provided as a part of the Module You may have to configure the selected port to 9600 baud as the default settings for all ports is 1200 baud Configure the selected port using menu devices port baud 3 The DB9 pigtail may be connected to any remaining available port other than COM 3 You may have to configure t...

Page 7: ...e the menu change password command on the Endec You will need the administrator s password to do this change and if it is not available consult section 14 3 of the SE1822 Endec User Guide or section 12 11 in the 3644 Digital Endec User Guide 11 Assure that the Decoder Active or Dec Rly relay is set to either the default Pending or to the Pending Done preferred relay program Go to menu relay and sc...

Page 8: ...Preview Audio button is pressed This is a timed and self muting function and turns off 5 seconds after the audio has ended Warranty Information The Ultimate Remote Control and Automation Interface Module are warranted for a period of one year from the date of purchase This warranty covers materials and workmanship only Any misapplication physical or electrical damage from outside sources or by the...

Page 9: ...ors supplied DB9 interface module with DB9 pigtail and Endec Automation control interface screw terminal connections Sage Endec Interface Serial RS 232 2 Endec ports required Power External power supply supplied Input 120VAC 50 60Hz Output 9VDC 350ma Power Cord Length approx 6 ft total Mounting Desktop Operating temperature 32 to 120F Humidity 0 to 95 non condensing Shipping Weight 4 lbs approxima...

Reviews: