have to configure the port to 9600 baud as the default setting is 1200
baud. Configure the ports using
menu.devices.port.baud
. Select another
available COM port for LED sign operation by selecting;
menu,devices.port.device.type.LED sign
and connect the DB9 pigtail to
this port. If the COM 3 port is selected, you may have to configure the
port to 9600 baud as the default setting is 1200 baud. Configure the ports
using
menu.devices.port.baud
..
3644 Digital:
1. To enable the required DC voltage to pin 9 of the COM ports, remove the
top cover of the Endec by removing the six retaining screws and slide the
cover plate toward the rear of the Endec. Locate “JP1” on the main green
PCB covering the bottom of the case. “JP1” is located towards the rear
left corner of the PCB. Do not confuse this “JP1” with the JP1 on the red
daughter card. You will find that the jumper is placed on only one of the
pins by factory default. Remove the jumper and place it on both pins of
“JP1” and replace the cover. Refer to section 13.2 of your Endec 3644
Digital User Guide and Reference Manual.
2. The Interface Module may be connected to COM 3, 4, 5, or 6 on the rear
of the Endec. Secure the Module to the Endec using the captive screws
provided as a part of the Module. You may have to configure the selected
port to 9600 baud as the default settings for all ports is 1200 baud.
Configure the selected port using
menu.devices.port.baud
.
3. The DB9 pigtail may be connected to any remaining available port other
than COM 3. You may have to configure the selected port to 9600 baud
as the default settings for all ports is 1200 baud. Configure the selected
port using
menu.devices.port.baud
.
General:
1. Attach the supplied twisted wire pair to the “Decoder Active” or “Dec Rly”
terminals on the rear of the Sage-Endec. Polarity is not important.
2. Attach the shielded wire to the “Speaker Line Out” and the closest “Audio
Common” or “GND” terminals. The shield goes to the “Audio Common” or
“GND” terminal.
3. Connect the twisted pair of wires from the Endec “Decoder Active” or “Dec
Rly” terminals to the DEC ACT INPUT on the Interface Module. Polarity
does not matter.
4. Connect the shielded conductor from the Endec “Speaker Line Out” and
“Audio Common” or “GND” terminals to the AUDIO and COMMON
connectors on the Interface Module. Shield goes to COMMON.
5. Connect any auxiliary control wiring you desire to the RWT, RLS PEND
inputs, Decoder Active Output and EOM output terminals. The RWT and
6