Initiate a warning of some type (Tornado, Earthquake, Etc.) from the Sage-Endec 
front panel. (This cannot be done from the Ultimate Remote Control). Again the LCD 
sign will display the warning message and the strobe will flash orange. Clear the 
sign on the Ultimate Remote Control.  
 
Initiate an Alert (CAE, etc.) from the Sage-Endec front panel. (This cannot be done 
from the Ultimate Remote Control). Again the LCD sign will display the warning 
message and the strobe will flash red. Clear the sign on the Ultimate Remote 
Control.  
 
In order to test the Pending Alert functions it will take receipt of an actual alert and 
the inputting of alert audio from another EAS encoder. This is done by connecting 
the MAIN/ALERT XLR output from another unit to either the “Monitor 1” or “Monitor 
2” input and the audio common terminals of the Sage-Endec under test and initiating 
an alert from the other unit. You will then be able to release the pending, kill the 
pending and preview the audio functions. The audio functions can be tested either 
using the speaker or earphones. Just turn on the audio by rotating the gain control 
clockwise to a comfortable level. Note that the audio is enabled only when the 
Preview Audio button is pressed. This is a timed and self muting function, and turns 
off 5 seconds after the audio has ended.  
 

Warranty Information:  

The Ultimate Remote Control and Automation Interface Module are warranted for a 
period of one year from the date of purchase. This warranty covers materials and 
workmanship only. Any misapplication, physical or electrical damage from outside 
sources or by the customer is not covered. The customer must pay shipping costs to 
the factory, and DME will pay shipping costs to return the warranted equipment to 
the customer. Any priority shipping costs are to be the responsibility of the customer 
as ground service is standard. Please contact the factory for an RMA number prior 
to any returns. Items returned without an RMA may be sent back to the customer 
unopened.  
 

Technical Support : 

If you have questions, experience difficulties with the product or require further 
information please contact DME at: 805-987-7881 or 800-249-0487, Contact 
technical support at: [email protected] or visit www.DMEngineering.com 
for the latest User Guide. 
  

Specifications: 

 

Case Dimensions (Remote Control): 8.4" wide X 4.3" deep X 1.2" high Case  

Dimensions (Interface Module): 3.5’ wide X 3” deep X 1” high Remote Control  

Case Material and Color: styrene plastic, light grey  

LCD Display Dimensions: 6 1/16 X 5/8  

Character Size: .453 X .265  

LCD Display: Yellow Backlight  

Summary of Contents for 3644

Page 1: ...OL AND AUTOMATION INTERFACE MODULE FOR THE SAGE ENDEC MODEL SE1822 and 3644 Digital E A S ENCODER DECODER Software Version 1 4 Rev 2 DM Engineering 2174 Chandler St Camarillo CA 91345 4611 805 987 7881 800 249 0487 www DMEngineering com 1 ...

Page 2: ...The Ultimate EAS Remote Control is a self contained microprocessor based device that interfaces with the Ultimate Interface module via a Category 5e cable of up to 50 in length RFI protection is included in the design to assure proper operation in both AM and FM RF environments The unit talks to the Sage Endec 1822 or Digital 3644 Encoder Decoder by means of a proprietary code and connects to the ...

Page 3: ...Endec 7 AUDIO GAIN This control adjusts the audio output level for both the internal speaker and earphones for the Preview Audio function It is provided with an off position to disable the internal audio amplifier if desired It is important to note that the RLS PEND KILL PEND and REVIEW AUDIO functions are only enabled when there is a pending alert active on the Sage Endec This prevents commands b...

Page 4: ...Output of the Sage Endec Please note that all audio alert tones digital signals and alert audio are present at this jack It may be used for a line input to a studio control board for alert playback using either the RLS PEND for the entire alert or the PREVIEW AUDIO audio portion only 4 LCD Contrast Control User screwdriver adjustable LCD contrast control This may be adjusted to accommodate the use...

Page 5: ...e DEC ACT OUTPUT relay function Installation The following menu Items and jumper connections must be set on the Sage Endec prior to connection of the Ultimate system It is advisable to remove power from the Endec prior to this installation to avoid accidental shorting within the Endec or initiation of a test Prevent damage to the Ultimate system by avoiding ground loops between the Ultimate interf...

Page 6: ... 4 5 or 6 on the rear of the Endec Secure the Module to the Endec using the captive screws provided as a part of the Module You may have to configure the selected port to 9600 baud as the default settings for all ports is 1200 baud Configure the selected port using menu devices port baud 3 The DB9 pigtail may be connected to any remaining available port other than COM 3 You may have to configure t...

Page 7: ...e the menu change password command on the Endec You will need the administrator s password to do this change and if it is not available consult section 14 3 of the SE1822 Endec User Guide or section 12 11 in the 3644 Digital Endec User Guide 11 Assure that the Decoder Active or Dec Rly relay is set to either the default Pending or to the Pending Done preferred relay program Go to menu relay and sc...

Page 8: ...Preview Audio button is pressed This is a timed and self muting function and turns off 5 seconds after the audio has ended Warranty Information The Ultimate Remote Control and Automation Interface Module are warranted for a period of one year from the date of purchase This warranty covers materials and workmanship only Any misapplication physical or electrical damage from outside sources or by the...

Page 9: ...ors supplied DB9 interface module with DB9 pigtail and Endec Automation control interface screw terminal connections Sage Endec Interface Serial RS 232 2 Endec ports required Power External power supply supplied Input 120VAC 50 60Hz Output 9VDC 350ma Power Cord Length approx 6 ft total Mounting Desktop Operating temperature 32 to 120F Humidity 0 to 95 non condensing Shipping Weight 4 lbs approxima...

Reviews: