Change PIN, factory setting PIN: 000 (Master PIN see service)
SELECT:
Change settings - touch the operating pad with the operating / programming key
ENTER:
Confirmation of all changes - touch the operating pad with the operating / programming key. The display
flashes 2 times for confirmation.
Timeout:
If no interaction takes place for a period, the device automatically returns to the previous display mode.
Example: Change PIN to 222
The new PIN is saved.
Change Feedback ( Pump function control)
SELECT:
Change settings - touch the operating pad with the operating / programming key
ENTER:
Confirmation of all changes - touch the operating pad with the operating / programming key. The display
flashes 2 times for confirmation.
Timeout:
If no interaction takes place for a period, the device automatically returns to the previous display mode.
Feedback = Pump function control: after receiving a correct pulse signal at PIN 2, the pump starts to work. During the
function of the pump (about 7 s) the output signal at PIN 4 is switching from High (+ 20...30 VDC) to Low (0 V). By counting
the signals of the pump function control there is a possibility to estimate the delivered quantity of lubricant and the remaining
quantity in the lubricant reservoir (delivery rate per pulse signal =0,15 cm³).
Factory setting: F 1 = Feedback “on”
Alternative:
F 0 = Feedback „off“