17
Vers. 20170705
Input break (pause) time (H: TIME = time between the lubrication intervals in hours) and cycle
(C: CYCLE = lubrication quantity) for every pump unit
Input H: Time (pause time) = time between the lubrication intervals in hours (1 to 240 h are possible)
Display: possible number -> H 0 to H 99 -> after -> 100 to 240, remark: 240h = 10 days
When H. TIME = 0, it is impossible to input cycles.
Input C: CYCLE (number of cycles) = delivery rate of one period (1 to 30 are possible, 1 cycle = 0,15 cm³)
Pump unit can be turned off by setting C: CYCLE = 0
Factory setting for every pump unit: H: TIME = 4h, C: CYCLE = 1
SELECT:
Change settings - touch the operating pad with the operating / programming key
ENTER:
Confirmation of all changes - touch the operating pad with the operating / programming key. The display
flashes 2 times for confirmation.
Timeout:
If no interaction takes place for a period, the device automatically returns to the previous display mode.
Select other pump unit or timeout: leave the menu.
Important: Changes of the parameters are only applied
Select pump unit via SELECT, indicated
by a green LED on the control panel.
Confirmation via ENTER
Input pause time (H: TIME) via SELECT,
240 hours are possible, confirmation via
ENTER
Input number of cycles C: Cycle via
SELECT, 30 cycles are possible,
confirmation via ENTER