BA FlexxPump 125 - 24 V_20181121_EN de 201811 27
External Control
7.1.3. Signal 3sec (two pump strokes)
The signal 3sec triggers two consecutive pump strokes and therefore two lubrication
processes.
The signal can be repeated after a certain pause time.
U
0 V
24 V
t
3 s
Tp
U
0 V
24 V
t
> 3 s
> 3 s
ML
ML
PIN 2
PIN 4
P
Tp: Pause time
ML: Motor run time
P: Pause between motor runs
Description
• The FlexxPump 125 sends a permanent output signal (high level) at PIN 4 to signal
readiness for operation to the controller. This signal must be available uninterruptedly for at
least 3 s before a control signal can be sent to the FlexxPump 125.
• The 24-V signal 3sec (2.9 s ... 3.1 s) can then be sent to the FlexxPump 125.
•
After the signal drops to 0 V, the pump’s first motor run starts and the FlexxPump 125
pumps lubricant.
The motor running time (ML) depends on the lubricant and the counter-pressure
(7 s ... 17 s).
•
At the end of the first pumping process, the FlexxPump 125 sends a pause signal
(P=0.5 s). Then the second motor run starts.
• The FlexxPump 125 can process the next signal 3 s after the end of the second motor run
at the earliest (pause time Tp at least 38 s).