Software applications
52
User’s Manual
DLoG ITC 7
Statistical information, for example, is generated by calling:
MPCCOM.EXE -i
PIC-Version: 4.00 MPCCOM-Version: : 1.7
Last Update: 01.01.2003 Actual Temperature : 26°C
Working hour backlight : 103h 30min or 4d, 7h and 30min
Working hour device : 103h 40min or 4d, 7h and 40min
Delay time : 900s Switchoff time : 180s
Brightness value : 0 Switchoff automatic : no
Brightness control : yes Heating automatic : no
BKL off while on Accu : no Accu option : no
Use delay while on Accu: no Shift key state saved : no
Backlight key off : no "+" & "-" keys off : no
Power key off : no Shift key off : no
Act. brightness saved : no Use switchoff auto : no
Wait for powerkey : yes Wait for ignition : no
Switch-on device count : 70 Powerkey-time : 2.0s
Switch backlight-volt : 78 Switch-on/off bkl-sw : 1
Powerkey sw-on count : 26 Powerkey sw-off count : 25
Ignition sw-on count : 0 Switch-off auto count : 0
PS-ON switch-off count : 0 Temp-sensor error count: 0
Overtemp sw-off count : 0 Lowtemp sw-off count : 0
Heating active startup : 0 Heating active working : 0
Startup temp -> min : 23°C Startup temp -> max : 49°C
Working temp -> min : 23°C Working temp -> max : 49°C
Actual shutdown reason : unknown Last shutdown reason : unknown