5.1.
Cooling through the supply of fresh air
The DLoG ITC 7 is cooled using a so-called passive cooling system. During passive
cooling, the waste heat generated inside the device is emitted from the surface of the
housing.
For this system to function properly, sufficient fresh air circulation is required.
Never install the system in a closed environment where the cooling air is unable to
dissipate accumulated heat to the outside.
Caution:
Property
damage
If the DLoG ITC 7 does not have access to fresh cooling air, it
may result in overheating and severe damage to the unit.
The maximum permissible ambient temperature for the entire
system needs to be taken into account for the concrete
application area.
5.1.1.
Temperature behavior on the back of the device
CAUTION
The housing temperatures on the back of the DLoG ITC 7 can be
up to 20 °C warmer than ambient temperature. Danger of burns
on the skin!