30
6500-065-K-7-08
DC MOTOR NEGA
TIVE OUTPUT
DC MOTOR POSITIVE OUTPUT
BA
TTER
Y NEGA
TIVE INPUT
BA
TTER
Y POSITIVE INPUT
24 V
AC COMMON
24 V
AC INPUT
ACTIV
A
TION OUTPUT
RADIO POWER Not used.
OPEN INPUT
COMMON Not used.
5.3 DIP-Switch Settings
5.2 DC System Description
Switch
Function
Setting
Description
Operation
Changes
Open Direction
Automatic
Power-up
Activation
OFF
ON
ON
OFF
OFF
OFF
OFF
Operator Type
Not Used
Not Used
Not Used
Do Not Adjust
Do Not Adjust
Timer Not Used
Charging LED
Orange to Second Terminal #5
Not Used
Not Used
1
2
3
4
5
6
7
8
Gate will automatically open when a power outage occurs.
Set so that the gate cycles to the open direction upon loss of AC power.
OFF
ON
OFF
When AC power is restored, an input (push button, loop, radio receiver, etc.) is
required to return the gate to normal operation.
When AC power is restored, a 1-second pulse is sent to the gate operator input to
automatically restore normal operation.
Must be in the
ON
position.
2340
DIP-Switches
Gate will automatically OPEN and stay open
during an AC power failure. DIP-Switch 3
setting will determine how operator will
return to normal operation once AC power
has been restored.
–
+
12 V
3 Amp/Hr
–
+
12 V
3 Amp/Hr
Batteries
To Secondary Operator
DC ON/OFF
Power Switch
Red
Black
Red/White
Red/White
DC Motor
Black/White
Green not used.
Purple to Second Terminal #8
White to Second Terminal #7
Diode
Orange to P2 Plug on Circuit Board
To Primary or Single Operator
Green to Main Terminal #5
Purple to Main Terminal #3
White to Main Terminal #13