SECTION 5 - OPTIONAL CONVENIENCE OPEN ADJUSTMENTS
The optional convenience open system installed in your vehicular gate operator is designed as a convenience enhancement only.
It is not designed or intended to provide continuous gate operation during a power outage. Its sole purpose is to provide a
method to open the vehicular gate to allow unimpeded traffic flow when the gate and access control system is without power. If
your access control system requires 100% power backup and continuous operation when primary (AC) power has failed, a
power inverter / backup system, such as DoorKing’s Model 2000, is required.
•
The convenience open system cannot provide continuous gate operation during a power outage.
•
This system cycles the gate to the open position one time only after AC power failure.
•
The convenience open system requires testing on a monthly basis to insure the batteries are fully charged and that the
system is operational.
•
The convenience open system uses two 12-volt, 3.0 amp-hour gel-cell batteries. These batteries should be replaced
every two years on average, or sooner if required.
•
Batteries are affected by temperature. Cold temperatures will reduce the effectiveness of the batteries. High temperatures
will result in a shortened battery life.
•
Batteries are not covered under warranty.
This convenience open system consist of a control board (2340-010), motor and power supply (batteries) providing a
completely redundant drive system to open the gate should a power outage occur. This system is not designed to maintain
continuous gate operation; rather it provides a convenient method to open a gate
ONCE
during adverse conditions. If continu-
ous gate and access control system operation is required, refer to the DoorKing Model 2000 Inverter / Backup Power System.
5.1 Operating Mode
Turn switch 1
ON
and the system will automatically
open the gate approximately 3 seconds after loss of
AC power. Automatic mode is
always
used for for
gates in general access applications such as gated
communities, apartment complexes, etc.
Switch 1
OFF
is not used.
Automatic Open after loss of AC Power
Once AC power is restored, the system’s control board
can be set to “
automatically re-key
” the gate operator
(switch 3
ON
) to establish normal operation, or can be
set to require a “
manual input
” (switch 3
OFF
) before
the operator resumes normal operation.
Restart Options once AC Power is restored
DIP-Switches
DIP-Switches