Primary Operator Conduit
Control
Box must
be properly
grounded.
Mounting Control Box with Conduit
Coaxial Cable
Antenna Kit
P/N 1514-073
(Sold separately)
Input Power
115 V
AC or
Solar
High
V
oltage
Loops
Operator(s)
From Secondary Operator if Installed (See below)
Junction
Boxes
Primary Operator
Secondary Operator
Junction
Box
Junction
Box
DoorKing interconnection cable (Sold separately) inside underground conduit
Interconnection Cable 30 feet. P/N 2600-755
Interconnection Cable 40 feet. P/N 2600-756
Interconnection Cable 50 feet. P/N 2600-757
Elbow
NO
Sweep
YES
Drain Pipe
Low
V
oltage
Low
V
oltage
Permanent wiring must be installed to the operator as required by local electrical codes (See the 115 VAC control box
Wiring/Owner’s manual or Solar control box Wiring/Owner’s manual to wire operator). It is recommended that a licensed
electrical contractor perform this work. Check local building codes prior to installing any permanent wiring to ensure all wiring
and connections comply with local electrical code requirements.
Position the desired control box on the wall,
close enough to the operator so the primary operator cable can be easily routed
inside the box.
Make sure that the control box is mounted high enough off the ground that it will
NOT
come in contact with
standing or flowing water.
This will damage the internal components
. Secure the control box to the wall with appropriate
hardware (not included). Control box has pre drilled mounting holes. All power and control wires should be routed to control
box in conduits with sweeps.
Never
run low voltage rated wire insulation in the same conduit as high voltage rated wire
insulation.
•
3/4” conduit recommended. Use only sweeps for conduit bends and
NOT
elbow connectors. Elbows will make
wire pulls very difficult and can cause damage to the wire insulation.
•
Remove fragile components from control box to protect them during installation if necessary.