6400-065-T-8-12

13

Primary Operator Conduit

Control 

Box must 

be properly 

grounded.

Mounting Control Box with Conduit

Coaxial Cable

Antenna Kit

P/N 1514-073

(Sold separately)

Input Power

115 V

AC or

Solar

High

V

oltage

Loops

Operator(s)

From Secondary Operator if Installed (See below)

Junction

Boxes

Primary Operator

Secondary Operator

Junction

Box

Junction

Box

DoorKing interconnection cable (Sold separately) inside underground conduit

Interconnection Cable 30 feet. P/N 2600-755
Interconnection Cable 40 feet. P/N 2600-756
Interconnection Cable 50 feet. P/N 2600-757

Elbow

NO

Sweep

YES

Drain Pipe

Low

V

oltage

Low

V

oltage

Permanent wiring must be installed to the operator as required by local electrical codes (See the 115 VAC control box 
Wiring/Owner’s manual or Solar control box Wiring/Owner’s manual to wire operator). It is recommended that a licensed 
electrical contractor perform this work. Check local building codes prior to installing any permanent wiring to ensure all wiring 
and connections comply with local electrical code requirements.

Position the desired control box on the wall, 

close enough to the operator so the primary operator cable can be easily routed 

inside the box.

 Make sure that the control box is mounted high enough off the ground that it will 

NOT

 come in contact with 

standing or flowing water. 

This will damage the internal components

. Secure the control box to the wall with appropriate 

hardware (not included). Control box has pre drilled mounting holes. All power and control wires should be routed to control 
box in conduits with sweeps. 

Never

 run low voltage rated wire insulation in the same conduit as high voltage rated wire 

insulation.

  3/4” conduit recommended. Use only sweeps for conduit bends and 

NOT

 elbow connectors.  Elbows will make  

  wire pulls very difficult and can cause damage to the wire insulation.

  Remove fragile components from control box to protect them during installation if necessary.

Dual Gate Operators Connection (115 VAC or Solar)

115 VAC Control Box

Summary of Contents for 6400 - UL 325 Class 1

Page 1: ...M O D E L S E R IA L V O L T S P H A S E A M P S 6 0 H z M A X G A T E L O A D Do orKing Inc Inglew oo d CA Gate Operator and Control Box Mounting Vehicular Swing Gate Operator To wire this operator and complete the installation refer to a specific control box Wiring Owner s manual CLASS CERTIFIED TO CAN CSA C22 2 NO 247 CONFORMS TO ANSI UL 325 VEHICULAR GATE OPERATOR HP 53382 MODEL SERIAL VOLTS P...

Page 2: ......

Page 3: ...ing Inc makes no representations or warranties with respect to this manual This manual is copyrighted all rights reserved No portion of this manual may be copied reproduced translated or reduced to any electronic medium without prior written consent from DoorKing Inc Class of Operation Model 6400 UL 325 Class I Type of Gate Vehicular Swing Gates Only Gate Operator Voltage 24 VDC Current 3 Amps Mot...

Page 4: ...es UL 325 Entrapment Protection Glossary Swing Gate Requirements Swing Gate Protection 1 3 3 3 4 5 6 7 8 INSTALLATION 9 9 10 11 12 13 14 15 15 16 17 18 Manual Key Release Installation of 6400 Drive Motor Orientation and Components Installation Mounting Control Box with Conduit Install Warning Signs In Ground Loops Photo Sensor Positions Accessory Items 6400 Primary Secondary 4302 Circuit Board Con...

Page 5: ...ess opening shall be designed to promote pedestrian usage Locate the gate such that persons will not come in contact with the vehicular gate during the entire path of travel of the vehicular gate The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and closing to reduce the risk of entrapment Swinging gates should not o...

Page 6: ...d and maintained serious injuries or death can result Be sure that the installer has instructed you on the proper operation of the gate and gate operator system Be sure that the installer has trained you about the basic functions of the required reversing systems associated with your gate operating system and how to test them These include reversing loops inherent reversing system electric edges p...

Page 7: ...c in which unauthorized access is prevented via supervision by security personnel This table illustrates the entrapment protection requirements for each of the four UL 325 classes A Inherent entrapment protection system B1 Provision for connection of or supplied with a non contact sensor photoelectric sensor or the equivalent When used as the PRIMARY device must be monitored B2 Provision for conne...

Page 8: ...for vehicular traffic flow at entrances or exits to areas such as parking garages lots or toll areas VEHICULAR HORIZONTAL SLIDE GATE OPERATOR OR SYSTEM A vehicular gate operator or system that controls a gate which slides in a horizontal direction that is intended for use for vehicular entrance and exit to a drive parking lot or the like VEHICULAR SWING GATE OPERATOR OR SYSTEM A vehicular gate ope...

Page 9: ...e vehicular gate ref UL325 56 8 4 b Not Allowed OK Closed Gates Gates shall have smooth bottom edges with vertical bottom edged protrusions not exceeding 0 50 inches ASTM F2200 4 3 If distance is greater than 4 inches entrapment protection for this area is required ASTM F2200 7 1 1 1 If distance is less than 16 inches entrapment protection in this area is required ASTM F2200 7 1 1 2 A B A B Closed...

Page 10: ...tomatic Exit Loop Minimizes the potential of the gate closing when a vehicle is present Number and placement of loops is dependent on the application Reverse Loop Minimizes the potential of the gate closing when a vehicle is present Number and placement of loops is dependent on the application Optional will provide an open command to the gate operator s when a vehicle is exiting the property Provi...

Page 11: ... UL 325 safety and ASTM F2200 construction standards The proper installation of the vehicular slide gate operator is an extremely important and integral part of the overall access control system Check all local building ordinances and building codes prior to installing this operator Be sure your installation is in compliance with local codes Hinges for the Gate Good hinges are essential for proper...

Page 12: ...foundation box pivot point Good Soil Drainage Concrete Foundation Box Position and Installation Foundation Box Pivot Point 3 3 3 1 1 2 drainage pipe Not supplied Plumb Run 3 4 conduit with sweeps from foundation box to where control box will be mounted 2 5 8 foundation box pivot point Junction Box Sample Hinges Good Soil Drainage Concrete 6 Driveway Foundation Box Drain pipe can connect to an exis...

Page 13: ... on the 6400 DO NOT weld gate frame to U Channel Protect the 2 release handles from welding sparks during welding Release Handle Foundation Box U Channel Dimensions After the foundation box has been mounted in concrete and the gate has been connected to it proceed to the next page to correctly orient drive motor and install components in the foundation box 15 3 4 Gate Frame U Channel D D 1 1 1 2 M...

Page 14: ...te to be in the correct Open clockwise position Note Precise Final limit adjustments will be made when wiring the operator See the selected control box Wiring Owner s manual Open Gate Close Gate Drive Arm Limit Plate Limit Plate Limit Plate Open Limit Assembly Position 4 Slo Dwn Purple White 3 Limit Gray White Close Limit Assembly Position Purple White 4 Slo Dwn Gray White 3 Limit Close Limit Asse...

Page 15: ...local building codes prior to installing any permanent wiring to ensure all wiring and connections comply with local electrical code requirements Position the desired control box on the wall close enough to the operator so the primary operator cable can be easily routed inside the box Make sure that the control box is mounted high enough off the ground that it will NOT come in contact with standin...

Page 16: ...essary Low Voltage Primary Operator Secondary Operator Solar Power Flexible Conduit Low Voltage Low Voltage Low Voltage 3 4 conduit recommended Coaxial Cable Antenna Kit P N 1514 073 Sold separately Primary Operator Conduit From Secondary Operator if Installed See previous page Drain Pipe Solar Control Box DO NOT use a 12 volt solar panel Damage WILL occur One 24 V 10 watt panel required for 18 Am...

Page 17: ...revent the gate from closing on a vehicle in these areas They will reverse the cycling of the gate while a vehicle is in or near the gate s swing pathway Loop Lead In Wires Low Voltage In Ground Loops Loop lead in wires are twisted approx 6 twists per foot in PVC conduit to the control box Install Warning Signs This DoorKing Swing Gate Operator is shipped with two warning signs The purpose of the ...

Page 18: ...1 Typical 27 5 Maximum Opening Direction Side View Wall If this space is less than 16 inches secondary entrapment protection is required in this area Gate Frame Closed Opening Direction Photo Beam Potential Entrapment Area Top View Top View Secondary Entrapment Protection Device In addition to the inherent reversing sensor system the Model 6400 has a 6 pin UL 325 terminal for the connection of pho...

Page 19: ... Model E3K R10K4 NR Loop Hardware DoorKing offers a complete line of loop components to complete your gate operator system See DoorKing s web site www doorking com See the free manual Loop and Loop Detectors Information PDF located at Doorking s technical web site www dkaccess com Magnetic Lock Magnetic Gate Lock Kit provides an excellent means to secure swing gates and is a fail safe device allow...

Page 20: ...n Yellow Orange 1 7 6 5 4 3 2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 1 7 6 5 4 3 2 Secondary Operator Primary Operator Important Secondary operator Motor wires Blue Brown MUST be reversed from the primary operator motor wires Blue wire 1 Brown wire 2 Orange wire 3 Red wire 4 Yellow wire 5 Green wire 6 Green Yellow wire 7 Brown wire 1 Blue wire 2 Orange wire 3 Red wire 4 Yellow wire 5 G...

Page 21: ...6400 065 T 8 12 19 ...

Page 22: ... Glasgow Avenue Inglewood California 90301 U S A Phone 310 645 0023 Fax 310 641 1586 6400 6400 6400 Gate Operator and Control Box Mounting Vehicular Swing Gate Operator To wire this operator and complete the installation refer to the specific control box Wiring Owner s manual 6400 065 T 8 12 ...

Reviews: