6400-065-T-8-12
11
The fabricated U-channel will vary depending
on the width of the gate frame (
D
).
Installation of 6400 Continued
Gate Connection to 6400
Apply Grease
Grease
Filler
Hole
Weld
U-channel
on both
sides of
the gate.
Important:
The weight of the
gate
MUST NOT
rest on the 6400.
DO NOT
weld gate frame to U-Channel.
Protect the 2 release handles from
welding sparks during welding.
Release
Handle
Foundation Box
U-Channel Dimensions
After the foundation box has been mounted in concrete and the gate has been
connected to it, proceed to the next page to correctly orient drive motor and
install components in the foundation box.
1
5
3/4”
Gate Frame
U-Channel
D
D + 1”
1 1/2”
Min.
3/
8
” thick metal min.
Fabricated U-Channel
Gate A
rm
U-Channel
Gate Frame
Summary of Contents for 6400 - UL 325 Class 1
Page 2: ......