37
skin and eyes. In case of contact with electrolyte, immediately wash the affected area
with plenty of water and contact the doctor.
3. Terms and Conditions of Installation, Storage, Transportation,
Implementation
1.
The device should be installed on any flat, stable, dry surfaces and does not require
additional mounting / reinforcement.
2. Storage of the device is allowed only in places where the temperature and humidity
does not exceed the values specified in section 5 "Technical parameters".
3. The conditions of transportation of the device are identical to the conditions of its
storage. It is not allowed to transport the device near sources of heat, containers with
liquid, in places with large accumulations of dust / dirt.
4. The device must be operated in accordance with the current legislation of the Russian
Federation.
5. After the end of the product’s service life, it must not be disposed of with normal
household waste. Instead, it must be recycled to the appropriate collection point for
electrical and electronic equipment for further processing and disposal in accordance with
federal or local law. By ensuring this product is disposed of correctly, you help conserve
natural resources and prevent damage to the environment and human health, which is
possible if not properly handled. More detailed information about the points of reception
and utilization of this product can be obtained from local municipal authorities or at the
enterprise for the removal of household waste
.
4. Installation and Start-Up Procedure
4.1 UPS installation
1.
Package contents:
•
UPS
•
Power cable
•
USB cable (only for USB / RS232 models)
•
CD with software (only for USB / RS232 models)
•
User’s manual
•
Passport
2.
Upon receipt of the product, check that all contents have no damage that may have
occurred during transportation. Retain the packaging and, in the event of damage,
contact the transport company or distributor.
3.
Place the device in an appropriate place with sufficient ventilation and away from
water, combustible and corrosive gases.
4.
The ambient temperature should be in range of 0–40 °C.
Leave at least 20 cm on all sides of the UPS to ensure sufficient ventilation.
Summary of Contents for INFO1200
Page 2: ......
Page 5: ...3...
Page 6: ...4...
Page 7: ...5 1 2 2 1 1 2 3 4 5 3 6 7 2 2 1 2 3 Info Info LCD 4 5 10 6...
Page 8: ...6 2 3 1 2 3 1 2 5 3 4 5...
Page 9: ...7 4 4 1 1 USB USB RS232 USB RS232 2 3 4 0 40 C 20 1 RJ11 IN OUT RS232 USB USB RS232 50 60...
Page 14: ...12 6 INFO800 INFOLCD800 7 INFO1200 INFOLCD1200...
Page 15: ...13 8 INFO1500 INFOLCD1500 9 INFO2000 INFOLCD2000...
Page 18: ...16 4 4 10 50 V R L A 1 2 3 4 5 6 7...
Page 19: ...17 9 2 batt dkc ru service_center 8 800 250 52 63 www dkc ru...
Page 20: ...18...
Page 21: ...19 Lingua Italiana...
Page 22: ...20...
Page 36: ...34 English language...
Page 37: ...35...
Page 45: ...43 Figure 4 Runtime graph INFO800 INFOLCD800 Figure 5 Runtime graph INFO1200 INFOLCD1200...
Page 50: ...48...
Page 51: ......
Page 52: ......