Diversified Power International Accusense Charge  1-48C017C Series Instruction Manual Download Page 8

7.3.  STAGE THREE - CONSTANT VOLTAGE CHARGE (Absorption 

Charge) 

  7.3.1.  Yellow L.E.D. remains illuminated continuously, but the charger 

now regulates voltage and not current. While the charger 
maintains a constant voltage, the charge current gradually 
decreases. 

  7.3.2.  When the charger has determined the battery pack has reached 

80-90% capacity, the Yellow and Green L.E.D.s both illuminate. 

  7.3.3.  This stage ends when the charge is replenished to 100% 

capacity. 

 

  7.4.  STAGE FOUR - CHARGE COMPLETE (Standby) 

  7.4.1.  Green L.E.D. only, illuminates continuously. The charger will 

also disconnect itself from AC power, thereby saving energy and 
cost. While connected to the battery, the microprocessor 
remains active to monitor battery voltage and to keep a record of 
elapsed time. The charger’s DC cord set can now be 
disconnected from the charging receptacle by grasping the plug 
body or handle and pulling the plug straight out of the 
receptacle. 

 

  7.5.  RECYCLE CHARGE STAGE FIVE 

  7.5.1.  Only after the completion of Stage 4, and after 14 days of time 

has elapsed, AND if the battery voltage falls below 48Vdc, the 
charger will reset itself; thereby automatically initiating a new 
charge cycle routine and restoring battery to full capacity. 

 

 If the charger is left connected to AC Power, and then the DC cord set 

plug is re-connected to another battery pack, the charger will restart a 
new charge cycle from the beginning (Stage 1). 

 

 If, during any part of the 5-Stage Charge process, AC power should 

happen to be disconnected, the microprocessor will momentarily stop 
its program and wait for restoration of AC power. Thereafter, charging 
will resume from where it left off. 

 

 If, while charging, the charger finds an abnormal charge condition, it 

will attempt to shutdown and indicate the ‘Condition’ by flashing one 
or all of its RED L.E.D.s.  Refer to the ‘Troubleshooting’ section for a 
description of the Charge Error Condition, if you encounter a flashing 
RED L.E.D. 

 

Summary of Contents for Accusense Charge 1-48C017C Series

Page 1: ...Trojan T875 Mode 3 Use for Trojan T105 Mode 4 Use for 36v Input 120Vac 10Aac 60Hz Output 48Vdc 17 14 Adc Safety Timer 17 Hours IMPORTANT READ AND SAVE THIS SAFETY INSTRUCTION MANUAL KEEP IT WITH OR N...

Page 2: ...ol implements an intelligent charge Full automatic disconnect from AC power after completion of charge After completion of charge charger will monitor battery voltage levels 2 Introduction The Diversi...

Page 3: ...ing its warranty period contact your dealer for a warranty replacement To reduce risk of electric shock unplug charger from AC outlet before attempting any maintenance or cleaning Personal Precautions...

Page 4: ...tepped on tripped over or otherwise subjected to damage or stress Extension cord must be properly wired and in good electrical condition and large enough for the AC rating of charger as specified in t...

Page 5: ...d on the charger are for daily reference The charger is factory preset to charge using one of four operating MODES Each mode is set to charge a particular Battery Pack as listed Mode 1 48V US Battery...

Page 6: ...cords charger or receptacles are damaged or distressed in any way Using the charger with any of the above symptoms could result in a fire property damage or personal injury Have your distributor deal...

Page 7: ...ick can be heard This is the charger s internal relay clicking ON The Power On L E D will illuminate to indicate that AC power is applied and the charger will then commence charging as described DPI S...

Page 8: ...or handle and pulling the plug straight out of the receptacle 7 5 RECYCLE CHARGE STAGE FIVE 7 5 1 Only after the completion of Stage 4 and after 14 days of time has elapsed AND if the battery voltage...

Page 9: ...TO AVOID DAMAGE TO THE CHARGER CORDS PLUGS AND CHARGING RECEPTACLE DO NOT PULL ON ANY OF THE CHARGER S CORDS DO NOT TWIST ROCK OR PULL THE PLUGS FROM THEIR MATING RECEPTACLES SIDEWAYS 9 TROUBLESHOOTIN...

Page 10: ...lash Flash Flash Battery Voltage High Charger s DC cord set possibly connected to a battery pack with voltage higher than the output rating of the charger Battery Polarity Reversed Check output connec...

Page 11: ...me size and same rating DO NOT MIX DIFFERING SIZES OR TYPES Never use charger for any purpose contrary to its intended purpose of charging lead acid batteries in accordance with ALL instructions print...

Page 12: ...bel 7 HDW015 Heatsink To Case Screw 8 HDS055 DC Cord Set Strain Relief 9 OPC052 DC Cord Set 10 HDW007 Transformer Mounting Nut 11 HDW070 Transformer Mounting Bolt 12 HDS057 Transformer Mounting Bushin...

Page 13: ...13...

Page 14: ...h of an express warranty stated herein DPI shall not be liable for any incidental consequential or special damages for breach of any expressed or implied warranty Except to the extent required by appl...

Reviews: