WARNING: DO NOT OPERATE THE CHARGER IF IT IS
MALFUNCTIONING. PERSONAL INJURY OR PROPERTY DAMAGE
COULD RESULT.
If any of the three red L.E.D.s flash, the charge cycle has terminated
prematurely. An abnormal charging condition was detected and charging
stopped due to a Charge Error Condition. Refer to the following Charge
Error Table for a description of the possible failure or condition.
CHARGE ERROR TABLE
Flashing L.E.D.s
Condition
Power
Abnormal
Detection
Battery Voltage High
Off
Off
Flash
Battery Polarity Reversed
Off
Flash
Off
Output Overload
Off
Flash
Flash
Charge Level Unbalanced
Flash
Off
Off
Excessive Charging Time
Flash
Off
Flash
Excessive Overload
Flash
Flash
Off
Excessive Discharged
Flash
Flash
Flash
•
Battery Voltage High. Charger’s DC cord set possibly connected to a
battery pack with voltage higher than the output rating of the charger.
•
Battery Polarity Reversed. Check output connector and ensure proper
polarity. Remake connections.
•
Output Overload. While charging, and, for example, under severe
motor loading, charger may shut down. This error is not very likely to
occur.
•
Charge Level Unbalanced. Caused by unbalanced battery condition.
Example: some batteries are at a much higher state of charge than
others. This may require replacement of the batteries. Refer to the
Equipment’s Operators manual for instructions on servicing the
battery pack.
•
Excessive Charging Time. Occurs when charging took too long.
Possible causes include: use of a battery load that is draining energy
from the battery while the charger is trying to charge that same
battery, aged or unbalanced battery conditions, etc.