7. 5-STAGE CHARGE 

 

 If the charger’s AC cord set is first connected to AC power, while the 

charger’s DC cord set is left unconnected, the L.E.D.s will remain off 
and no power is delivered to the charger’s internal circuitry due to an 
internal relay, which remains in the ‘OFF’ state. 

 If the charger’s DC cord set is first plugged to the charging receptacle, 

while the AC cord set is left unconnected, approximately 3 seconds 
after connection, (and assuming the use of the

 

charger set to MODE-

2), all 5 charger L.E.D.s will flash on and off, twice, and then all 
L.E.D.s will turn off. The charger will remain in this idle mode, with all 
L.E.D.s off, until AC power is connected. 

 Immediately, upon connection of the charger’s AC cord set to AC 

power, a ‘click’ can be heard. This is the charger’s internal relay 
clicking ‘ON’. The ‘Power On’ L.E.D. will illuminate to indicate that AC 
power is applied, and the charger will then commence charging as 
described. 

 

DPI’S 5-Stage Charging Process works as follows: 

 

  7.1.   STAGE ONE - PRE-QUALIFICATION TEST 

7.1.1.  Yellow, Light Emitting Diode (L.E.D.), flashes on and off  

SLOWLY at a rate of once every 2 seconds during this stage. 
This stage applies tests to the battery pack. Further charging is 
prohibited if the charger discovers a fault such as connection to 
a 72V battery pack or reversed battery connections. Refer to 
Section 9 - ‘Troubleshooting’ for understanding faults. 

7.1.2.   The duration of this stage is dependent on the condition of your  

battery - approximately 45 seconds under average 
circumstances, but if your battery pack was allowed to severely 
discharge to less than 42v, then this stage can last as long as 
5hrs. 

 

  7.2.  STAGE TWO - CONSTANT CURRENT CHARGE (Bulk Charge) 

7.2.1.  Yellow L.E.D. illuminates continuously indicating that the charger 

is charging the battery at the full rated output. 

 

Summary of Contents for Accusense Charge 1-48C017C Series

Page 1: ...Trojan T875 Mode 3 Use for Trojan T105 Mode 4 Use for 36v Input 120Vac 10Aac 60Hz Output 48Vdc 17 14 Adc Safety Timer 17 Hours IMPORTANT READ AND SAVE THIS SAFETY INSTRUCTION MANUAL KEEP IT WITH OR N...

Page 2: ...ol implements an intelligent charge Full automatic disconnect from AC power after completion of charge After completion of charge charger will monitor battery voltage levels 2 Introduction The Diversi...

Page 3: ...ing its warranty period contact your dealer for a warranty replacement To reduce risk of electric shock unplug charger from AC outlet before attempting any maintenance or cleaning Personal Precautions...

Page 4: ...tepped on tripped over or otherwise subjected to damage or stress Extension cord must be properly wired and in good electrical condition and large enough for the AC rating of charger as specified in t...

Page 5: ...d on the charger are for daily reference The charger is factory preset to charge using one of four operating MODES Each mode is set to charge a particular Battery Pack as listed Mode 1 48V US Battery...

Page 6: ...cords charger or receptacles are damaged or distressed in any way Using the charger with any of the above symptoms could result in a fire property damage or personal injury Have your distributor deal...

Page 7: ...ick can be heard This is the charger s internal relay clicking ON The Power On L E D will illuminate to indicate that AC power is applied and the charger will then commence charging as described DPI S...

Page 8: ...or handle and pulling the plug straight out of the receptacle 7 5 RECYCLE CHARGE STAGE FIVE 7 5 1 Only after the completion of Stage 4 and after 14 days of time has elapsed AND if the battery voltage...

Page 9: ...TO AVOID DAMAGE TO THE CHARGER CORDS PLUGS AND CHARGING RECEPTACLE DO NOT PULL ON ANY OF THE CHARGER S CORDS DO NOT TWIST ROCK OR PULL THE PLUGS FROM THEIR MATING RECEPTACLES SIDEWAYS 9 TROUBLESHOOTIN...

Page 10: ...lash Flash Flash Battery Voltage High Charger s DC cord set possibly connected to a battery pack with voltage higher than the output rating of the charger Battery Polarity Reversed Check output connec...

Page 11: ...me size and same rating DO NOT MIX DIFFERING SIZES OR TYPES Never use charger for any purpose contrary to its intended purpose of charging lead acid batteries in accordance with ALL instructions print...

Page 12: ...bel 7 HDW015 Heatsink To Case Screw 8 HDS055 DC Cord Set Strain Relief 9 OPC052 DC Cord Set 10 HDW007 Transformer Mounting Nut 11 HDW070 Transformer Mounting Bolt 12 HDS057 Transformer Mounting Bushin...

Page 13: ...13...

Page 14: ...h of an express warranty stated herein DPI shall not be liable for any incidental consequential or special damages for breach of any expressed or implied warranty Except to the extent required by appl...

Reviews: