3. Remove the Retainer Housing (D8) with the 4mm hex and lift the Handwheel (D9) from the body –
Fig. 9.
Fig. 9
4. Insert the First Stage Body Holding Tool into one of the high pressure ports and clamp the tool into
a vise – Fig. 10.
NEVER CLAMP THE FIRST STAGE BODY INTO THE JAWS OF A VISE!
Fig.10
Caution Note: Clamping the body of the regulator into the jaws of a vise may
result in damage to the body that will require replacement of the regulator.
Always use a first stage holding tool to secure the regulator.