5
.
Second Stage Disassembly
(1) Additional tips for performing disassembly of the D6 Second Stage can be found in our video at:
https://www.youtube.com/watch?v=W12VDuCKOCE
(2)
Ensure the system is depressurized. The use of small, clean containers to hold parts is
recommended.
(3) In the following steps, the part numbers from the schematic will be used with their description. The
numbers on the photos also correspond with the parts list on the schematic. Items in the service kits
are identified in the same way. Have both in front of you while following the instructions. Be sure to
keep all old parts organized and separate from new ones in the service kit. The old washers and O-rings
marked with an asterisk (*) will be replaced with new ones from the service kit and the remaining parts
will be cleaned and reused. Take care with O-ring (04*) and O-ring (20*) as they are very close in size.
1. Remove the Second Stage from the hose. The Main Housing cover consists of the Purge Button
Retainer (08), Purge Button (09) and Top Cover (10). Unscrew the cover from the Main Housing (01) -
Fig. 4. Remove the Diaphragm Washer (07) and the Diaphragm (06). This reveals the Adjust Tube
assembly in the Housing - Fig. 5.
Fig. 4 Fig. 5