the
TENS
mode is now shown on the display ( flashes - see
Fig. 23
).
21
Fig. 23
9
12.7 Use of accessories
Particularly when using the
special programmes for 6 different parts of the body
,
you can also comfortably connect the DITTMANN textile electrodes and/or the back pain
relief belt, knee pain relief cuff or neck cuff available as accessories to the device. The
following products are suitable for use for these programmes:
(H):
Special programmes for the
hand: stimulation glove HFE 322
(F):
Special programmes for the
foot: stimulation sock SFE 323
(N):
Special programmes for the
neck: neck cuff TNM 275
(E):
Special programmes for the
elbow joint: elbow electrode EFE 361
(K):
Special programmes for the
knee joint: knee pain relief cuff KMT 285
and
knee electrode KFT 362
(B):
Special programmes for the
back: back pain relief belt RGT 284
and
back pain
relief belt RFT 363
When using these products together with the TENS/EMS device TEN 250, please always
follow the operating instructions of these additional products and, above all, the
respective safety instructions!
NOTE:
If no key is pressed in the setting mode for approx. 30 seconds, the setting mode
is automatically terminated with an acoustic signal. The display
SET
goes out, the
adjustable values stop flashing and the device switches into the basic mode. If no other
key is pressed for a further 3 minutes, the device switches off automatically.
USAGE
12.5 Deleting the settings
The settings you have made in the adjustable programmes are
stored in the device and can be recalled. If you wish to delete these
settings and to reset the programmes to the basic settings, you can
proceed as follows: Open the cover of the battery compartment
(see also p. 12) and remove one of the four batteries. Press and
hold the key
(CH2 )
while re-inserting the fourth battery. The
blue display lighting switches on and shows an empty display. After
several seconds, two acoustic signals are generated and all adjust-
able programmes are reset to the basic factory settings according
to table (p. 22 - 26). In the basic mode, the programme 1 (
P01
) of
4
4
12.6 Switching off the device
In the operating mode, the device switches into the basic mode whilst an acoustic signal
is generated when the programme time has run out. Press and hold the key
( )
for
several seconds in order to switch off the device completely.
NOTE:
If none of the keys is pressed, the device switches off the blue display lighting
after approx. 20 seconds. Approx. 1 minute after the last key has been pressed, a short
acoustic signal is generated; after approx. 2 minutes, two short acoustic signals are
generated and, after approx. 3 minutes, three short acoustic signals are generated.
Afterwards, the device switches off automatically. If desired or in an emergency situation,
however, you can always switch off the device at any time by pressing the key
( )
for
several seconds.
GB
4. PJN157-14_GA-GB_HHD_TEN250_31.03.14
Montag, 31. M
rz 2014 12:10:42