Operating modes and configuration
DEU
ENG
ENG
49
2. Select the symbol ”
“ and confirm the selection by shortly pressing the wheel.
The following sub-items are available in the menu by turning the setting wheel:
“type”
for switching the base station between heating and cooling modes (
dis-
abled when the Multi-IO Box is connected
).
1. Select “HEAT” for heating or “COOL” for cooling by turning the setting wheel (E)
and confirm your selection by pressing.
“Pr.nr”
for selecting the week profile number (“no. 1, no. 2 ... no. 6“).
1. Select the number of the desired profile by turning and confirm your selection
by pressing briefly.
“Pr.Ad”
for the individual setting of the week profiles (“no. 1, no. 2 ... no. 6“). In
the week profile, up to 6 heating phases (13 switching times) can be set for the
selected heating profile for each day of the week. Programming is possible for the
selected days for a period from 00:00 to 23:59.
1. In the menu item “Pr.Ad”, select the number of the desired profile by turning the
setting wheel (E) and confirm your selection by pressing briefly.
2. Select the desired option Weekday/Workdays/Weekend/All days by turning the
setting wheel (E) and confirm your selection by pressing briefly.
3. Confirm the start time 00:00 by briefly pressing the setting wheel (E).
4. Select and confirm the desired temperature for the start time by turning/pressing.
5. Select and confirm the time shown in the display by turning/pressing the set-
ting wheel.