Operating modes and configuration
49
DEU
ENG
ENG
“Pr.nr” for the selection of the week profile number (“no. 1, no. 2 ... no. 6”).
1. Select the number of the desired profile and confirm the selection by shortly
pressing the setting wheel.
“Pr.Ad” for the individual setting of the week profiles („no. 1, no. 2 ... no. 6“). Up
to 6 heating phases (13 switch-over points) can be set in the week profile for every
week day for the selected heating profile. Programming is made for the selected
days for the time from 00:00 to 23:59 o’clock.
1. In the menu item “Pr.Ad”, select the number of the desired profile by turning
the setting wheel (E) and confirm the selection by shortly pressing the wheel.
2. Select the desired week day/working day/weekend/all days by turning the setting
wheel (E) and confirm the selection by shortly pressing the wheel.
3. Confirm the start time of 00:00 o’clock by shortly pressing the setting wheel (E).
4. Select the desired temperature for the starting time by turning/pressing and confirm.
5. Select and confirm the time indicated in the display by turning/pressing the
setting wheel.
6. Select the desired temperature for the set period by turning/pressing and confirm.
7. Repeat the process for the complete period from 00:00 to 23:59 o’clock.
Week profile 1-3: Heating, 4-6: Cooling
In case of a CO signal the program changes from heating or cooling auto-
matically according to the following scheme:
1 (heating) to 4 (cooling), 2 (heating) to 5 (cooling), 3 (heating) to 6 (cool-
ing) resp. vice versa.