6. ELECTRICAL CONNECTIONS
6.1 POWER SUPPLY AND LIMIT SWITCH CONNECTION WITH CABLE DITEC NRGCAB AND
DITEC CONTROL UNIT
6.2 POWER SUPPLY AND LIMIT SWITCH CONNECTION WITHOUT CABLE DITEC NRGCAB
If standard cable Ditec NRGCAB is NOT use it is recommended for:
-
Motor power supply
: remove the black power supply terminal and crimping the connections in compliance with Good
Practice and current practics the legend of 6E figure.
-
Limit switch connection
: use a cable with AMP 0172168 clip on the both extremity and wired up as shown in figure 6F.
Fig. 6A
1
2
3
4
Fig. 6E
F
In case the motor turns in the wrong direction, invert the two wires of the phase (L1, L2 and L3) on the
F
connector.
Ditec NRG100TXE, NRG100TRE e NRG140TXE
Ditec NRG100TXE, NRG100TRE e NRG140TXE
Ditec NRG100TXF
1
2
3
4
5
6
1
2
3
4
5
6
Fig. 6B
Fig. 6F
1
2
3
4
5
6
1
2
3
4
5
6
SECURITY
SECURITY
AUXILIARY
CONTROL 2
AUXILIARY
CONTROL 1
Ditec NRG100TXF
Fig. 6D
POWER SUPPLY
1
PHASE
2
PHASE
3
GROUND
4
PHASE
Fig. 6C
WARNING!
Before the limit switch adjustment, on the EL500E cen-
tral unit check the parameter 11 set up.
NRGCAB
NRGCAB
6 PIN CABLE CONNECTOR
1
GRAY
UP LIMIT SWITCH
2
GREEN OPEN BUTTON
3
WHITE
COMMON
4
YELLOW CLOSE BUTTON
5
PINK
DOWN LIMIT SWITCH
6
BROWN SECURITY
Be careful to connect the common and the
two senses (down and up) in the shown po-
sitions.
L
It is recommended to use the cable type Ditec NRGCAB to connect Ditec control unit (EL400 or EL500E) to the NRG motor:
- Insert the supply terminal as shown in the 6A and 6B figures (fix it as arrows indicate).
- Insert the limit switch 6 pins clip (
L
) as figures 6C and 6D illustrate.
L
WARNING!
Before the limit switch adjustment, on the EL500E central unit check the parameter 11 set up.