- 36 -
0DT869 2019-01-30
6 PROGRAMMING MENU
STEP 1
st
level options
2
nd
level options
Menu scrolling
Notes
1
Select language
Confirm with:
Confirm with:
ENGLISH
ITALIAN
FRANÇAIS
DEUTCH
ESPANOL - POLSKA
CESKY - MAGYAR
2
Door model
Confirm with:
Confirm with:
SOFT RESET
SECTOR RESET
SMART PLUS
SECTOR PLUS
TRAFFIC C
SMART RESET
3
Position control
Confirm with:
Confirm with:
ENCODER
LIMIT SWITCH
4
Motor control
This option is only displayed if door with
external motor is selected in point 3).
Confirm with:
LEFT
RIGHT
5
Calibrating positions
The door will move to the desired
position in man present mode and at
low speed.
Confirm position with:
Confirm with:
CLOSED POSITION
PARTIAL OPEN POS.
OPEN POSITION
6
Command mode
Confirm with:
Selecting 1-9: if 1-9 is closed, the
command mode will be impulsive, if
1-9 is open the command mode will be
“dead man”
Confirm with:
IMPULSIVE
MAN PRESENT
INPUT 1-9
7
CONFIRM DATA
Confirm with:
6.1 INSTALLATION MENU
When the control panel is switched on, after showing the messages DITEC ENTREMATIC and microprocessor and card FW
VERSION, the device automatically enters the installation menu and displays the message SELECT LANGUAGE.
PROGRAMMING COMPLETED
The door is now programmed and operating (with automatic closing and pulse command) with the set default speed values.
With the door MOVING, the voltage and current values will be displayed on the BUS.
Confirm with
Remove cables from PIN 3, 4, 20 during programming
Summary of Contents for 0DT869
Page 22: ...22 0DT869 2019 01 30...
Page 24: ...DESSINS INSTALLATION M CANIQUE X Y 4 D C 3...
Page 25: ...MECHANICAL INSTALLATION DRAWINGS 90 9 STOP C NO DS V W U M4x8 7 5 6 E F...
Page 27: ...27 0DT869 2019 01 30...
Page 46: ...46 0DT869 2019 01 30 3 5 1 1 4 2 STOP 6 A B C 1 m EMERGENCY EXIT RESTORE CURTAIN INSTRUCTION...