11
5.6 Membrane Vent
Membrane vents enable the free passage of gases and vapors and allow
for the equalization of the pressure between the internal case and ambient
conditions. This helps to protect and preserve the internal components of the
battery.
6. INSTALLATION
WARNING
ELECTRIC SHOCK AND FIRE HAZARD:
This equipment must only be installed as
specified. Do not disassemble or modify the battery. If the battery case has been
damaged, do not touch exposed contents. No user-serviceable parts inside.
Failure to follow these instructions may result in injury.
CAUTION
FIRE AND BURN HAZARD:
Do not cover or obstruct the heat sink or install the battery in
a zero-clearance compartment. Compartment ventilation is required.
Failure to follow these instructions can result in minor to moderate injury.
NOTE
It is the responsibility of the installer to ensure that all applicable installation
requirements and standards are met.
6.1 Tools
• Insulated tools sized to match nuts, bolts, and cables in use
• RMS type Voltmeter
• Post cleaner and wire brush
• Personal protective equipment
6.2 Location
The battery should be installed in locations that meet the following requirements:
1. Do not install in direct sunlight.
Avoid installing the battery in an area
with high ambient temperature.
2. Moderate temperatures.
Ambient temperatures of 15°C to 20°C (59°F
to 68°F) are ideal for extending LiFePO
4
battery life. Do not install in the
Engine Bay as this will expose the battery to elevated temperatures
greater than 40°C (104°F).
3. Ventilated.
Do not install in zero-clearance compartments. Maintain at
least 50 mm (2 inches) above the top cover for open airflow.
4. Proper orientation.
The battery may be installed in any orientation
other than upside down. Do not install upside down.
5. Hold-downs.
The battery is designed with standard B1/B3 hold-down
ledges for use with standard battery trays. The battery may also be
strapped in place with over-the-top holds.