![DISCOVER LITHIUM BLUE DLB-G24-12V Installation And Operation Manual Download Page 22](http://html1.mh-extra.com/html/discover/lithium-blue-dlb-g24-12v/lithium-blue-dlb-g24-12v_installation-and-operation-manual_2508834022.webp)
22
Table 10-1.
DLB Fuse Specifications
Discover Part Number
170-0035
170-0033
Fuse Rating
200A
75A
Applicable
DLB-G24-12V
DLB-GC12-12V
DLB-GC12-24V
DLB-G24-24V
DLB-G24-36V
Fuse Terminal Torque
13 Nm (9.6 ft-lb)
This task should be performed by qualified personnel:
• Use only Insulated tools
• Wear Personal protective equipment
• The battery system must be de-energized
• Battery cables must be disconnected
• Battery terminals must be protected from short-circuiting and touch
Refer to
Section 6.5
Terminal Connections and Hardware
,
Section 6.6
Single Battery
Installation Procedure
and
Section 6.7
Parallel Battery Installation Procedure
.
1. Ensure that the DC system is de-energized and, the battery charger and
all loads are disconnected. If the battery is in a DC circuit of equipment
has a disconnect, open the disconnect to isolate the battery.
2. If connected to others, remove the battery and isolate it.
3. Protect the battery terminals from short-circuiting and touch by
covering them with terminal covers or electrically rated tape.
4. Install the fuse on the battery fuse post. The battery will not operate if
the battery fuse is installed on the battery terminal post.
5. Remove the nut holding the fuse and replace it with a new fuse paying
strict attention to orientation and the fuse ratings in
Table 10-1
DLB Fuse
Specifications
.
6. Torque the nut holding the new fuse to 13 Nm (9.6 ft-lb).
7. After removing the terminal protection, reinstall the battery into the
system.
8. If installed, close the disconnect to complete the circuit of equipment
and energize the battery system.
NOTICE
Failure to properly torque battery terminal nuts may increase resistance and lower voltage
which may lead to burnout of the terminals and void the warranty.
11. STORAGE
Leaving the battery connected to a trickle load, or to power electronics will
cause the battery to be discharged during storage. Without any load, the
battery will self-discharge by approximately 3% per month while in storage.
After storage, charge the battery to 100% SOC and then perform at least 1 full
discharge and charge cycle before returning the battery to service.
Summary of Contents for LITHIUM BLUE DLB-G24-12V