5
2. SPECIFICATIONS
Specifications are published at 25
o
C / 77
o
F
2.1 Electrical Specifications
Table 2-1.
DLB Electrical Specifications
Electrical Spec
DLB-G24-12V DLB-G24-24V DLB-G24-36V DLB-GC12-12V DLB-GC12-24V
Nominal Voltage
12.8 V
25.6 V
38.4 V
12.8 V
25.6 V
Energy
1280 Wh
1167 Wh
1167 Wh
2560 Wh
2560 Wh
Capacity 1Hr
100 Ah
45.6 Ah
30.4 Ah
200 Ah
100 Ah
Reserve Capacity 25A
240 minutes
120 minutes
76 minutes
480 minutes
240 minutes
Charge Bulk Voltage -
Bulk VDC
13.8 - 14.2 V
27.6 - 28.4 V
41.4 - 42.6 V
13.8 - 14.2 V
27.6 - 28.4 V
Charge Absorption
Voltage - U1 MAX
13.8 V
27.6 V
41.4 V
13.8 V
27.6 V
Charge Float Voltage - U2
13.6 V
27.2 V
40.8 V
13.6 V
27.2 V
Charge Termination
Current
a
2.5 A
1.15 A
0.75 A
5 A
2.5 A
Low Voltage Disconnect
Voltage
12 V
24 V
36 V
12 V
24 V
Max. Continuous
Discharge Current
100 A
45 A
30 A
150 A
100 A
Nominal Charge Current
50 A
22.5 A
15 A
100 A
50 A
Max. Continuous
Charge Current
100 A
45 A
30 A
150 A
100 A
Peak Discharge Current
(2 seconds)
250 A
120A
120 A
250 A
250 A
Fuse
200 A
75 A
75 A
200 A
200 A
a
Charge current termination is permitted to be less than specified. When the charger termination current is lowered
the internal balancing function has more time to operate.
CAUTION: Hot Surfaces. Do not touch when hot.
CAUTION: Heavy Object. When lifting, follow appropriate
standards.
Do not dispose of the battery in the garbage. Do not dispose of
the battery in fire.
Use personal protective equipment when working with batteries.
Additional information concerning important procedures and
features of the battery. Read all the instructions before installation,
operation, and maintenance.
This product must be recycled and is made of recyclable materials.