Z-Wave
Configuration Parameters
Parameter No.
Definitions
Parameter Value
25 (0x19)
Indicate a location for IR code
learning and start learning
0-22 (0x00 0x16)
26 (0x1A)
Learning status register
Note:
The status value 0x01 and
0x04 will be reset to 0 when
the ZXT-120 receive a get
command to this parameter
0(0x00)
:
Idle - this IR channel
is idle (default)
1(0x01)
:
O K - t h e l a t e s t
l e a r n i n g p r o c e s s
s u c c e s s f u l a n d
completed
2(0x02)
:
Learning - the ZXT-
1 2 0 i s b u s y
processing previous
learning request
4(0x04)
:
Failed - the latest
learning request failed
27 (0x1B)
IR code number for built-in
code library
Refer "Code list" for details
28 (0x1C)
External IR Emitter power
level
0(0x00)
:
normal power mode
255(0xFF)
:high power mode
(default)
32 (0x20)
Surround IR control
- to avoid the IR interference
b y d i s a b l i n g t h e
surrounding IR emitter if 2
air-conditioners in a room
are used
- extend the battery life by
disabling the Surround IR
Emitters
0(0x00)
:
disable Surround IR
Emitters
255(0xFF)
:enable Surround IR
Emitters (default)
15