Rev.: 20170407
Platform: DBALL2
Firmware: GM9 Range Extender Ready (RXT) Installation v.2.05+
© 2017 Directed. All rights reserved.
Page 11
LED Diagnostics & Troubleshooting
LED
Description
Troubleshooting
Module Programming
Module has no power.
Check the power connections.
Module is powered. Waiting to receive the first
part of the information from the key.
Check your connections (see wiring diagram).
Information received from the key.
Check your bypass connections (Yellow/Black wire) and make sure the
battery is removed from the key fob. Make also sure the key is in key port
(or key reader.)
Waiting to receive the second part of the
information from the key.
Normal operation.
Bypass was skipped.
Normal operation.
All information received from the key.
A 5 seconds delay can be necessary to receive all information from the key.
OBD CAN is detected, the device is ready for
Key2GO programming.
Check OBD CAN connections (see wiring diagram).
Module was successfully programmed.
Normal operation.
Module was successfully programmed without
transponder.
Normal operation.
Module Programming - Error codes
SW CAN not detected.
Check the LT green wire connections. Wake up the data bus by turning the
ignition on and try again.
OBD CAN not detected.
Check the Tan - Tan/Black wire connections. Wake up the data bus by
turning the ignition on and try again.
Bypass data not detected.
Check the bypass line connection. If more than one wire is used, make sure
they are not inverted. Start vehicle using the key to confirm the OEM
equipment is still operational.
External Module Synchronisation
OBDII feature not supported.
Diagnostic data bus not detected. Some features are not supported by
SmartStart. This can be caused by missing wire connections or module
hardware limitation. Refer to the wiring installation section to check the
connections.
Active Ground While Running
GROUND OUT ON (GWR) command received.
Otherwise, the Ground While Running (status) signal was lost or was never
received by the module. Commands can come from RF, D2D or W2W.
IGNITION ON command received.
Otherwise, the ignition signal was not received by the module. In a W2W
install, it will show only if the ignition input wire is used.
START ON command received.
Otherwise, the start signal was not received by the module. In a W2W
install, it will show only if the ignition input wire is used.
Solid
Red
Solid
Green
Solid
orange
Solid
orange
x3 sec
Solid
green
x3 sec
Flashes
orange
Flashes
green
Off
Flashes
red x 1
Flashes
red x 2
Flashes
red x 3
Flashes green
& orange
Flashes
green
Flashes
green
quickly
Flashes
red, red,
orange
Flashes red
& orange
Go to the next page to see the rest of the LED Diagnostics & Troubleshooting.