12
© 2012 Directed. All rights reserved.
Menu 2 - Advanced
M e n u
Item
One-chirp setting
Two-chirp setting
1
30 second siren duration
60 second siren duration*
2
Nuisance Prevention Circuitry On
Nuisance Prevention Circuitry OFF
3
Progressive door trigger
Instant door trigger
4
Disarm from Valet, 1 pulse
Disarm from Valet, 2-5 pulses
5
Door trigger error chirp ON
Door trigger error chirp OFF
6
Ignition controlled domelight On
Ignition controlled domelight OFF
7
Unlock output 1 pulse
Unlock output 2 pulses
8
Lock output 1 pulse
Lock output 2 pulses
9
Factory disarm with trunk release ON
Factory disarm with trunk release OFF
10
FAD function with Unlock (1)
Before Unlock (2), Remote Start only (3)
11
FAD 1 pulse
2 pulses
12
AUX 2 validity (1)
Latched (2), Latch reset with ignition
(3), 30-secs timed (4), 60-secs (5), 90-secs (6)*
13
AUX 2 Linking None (1)
Arm (2), Disarm (3), Remote Start (4)
14
AUX 3 validity (1)
Latched (2), Latch reset with ignition
(3), 30-sec. timed (4)60sec(5)90sec(6)*
15
AUX 3 linking None (1)
Arm (2), Disarm (3), Remote Start (4)
16
AUX 4 validity (1)
Latched (2), Latch reset with ignition (3), 30-sec. timed (4) 60sec (5) 90
(6)*
17
AUX 4 linking None (1)
Arm (2).Disarm (3), Remote Start (4)
*Additional settings using the Bitwiter®.
Menu 2 - Descriptions
1.
Siren Duration
:
1. 30sec:
the siren output for full trigger activations and Panic mode is 30 seconds
2. 60sec: the siren output for full trigger activations and Panic mode is 60 seconds
2.-
Nuisance Prevention® Circuitry (NPC)
1. On
: sensors that trigger excessively will be defeated until they have been stable for more than one hour.
2. Off: sensors will not be defeated if triggered excessively
3.
Progressive Door Trigger
1. On:
When the door is opened with the system armed, the siren will chirp 10 times prior to the full triggered sequence.
2. Off: The full siren output will occur the moment the door is opened.
4.
Valet Disarm Pulse Count
•
1-5: sets the number of presses (1-5) on the Control Center Button required to override the alarm system.
5. Door Trigger error Chirp
1. On:
if the door trigger is active when arming, the siren will emit an additional chirp as an alert
2. Off: an active door trigger when arming will not create an alert output.
6. Ign-controlled Dome light
1. On:
the system will turn on the dome light for 30 seconds when the ignition is turned off.
2. Off: the system does not turn on the dome light when the ignition is turned off.
NOTE: the dome light supervision option must be installed.