6 OF 8
IG022719-1.0
HYDROLUME
®
SLIM 24V LED STRIP LIGHT
INSTALLATION GUIDE
HYDROLUME
®
SLIM 24V LED Strip Light
INSTALLATION GUIDE
Shift in
brightness
and/or kelvin
• Ensure an appropriate gauge of
wire is installed between strip light
and LED driver.
See VOLTAGE
DROP CHARTS.
Some LEDs
are not
functional
• Ensure strip light has not been bent
excessively, which could damage
circuitry.
• Ensure strip light has not been
submerged in any liquid for any
amount of time.
Lights are
flickering
• Ensure a compatible driver and/or
dimming control is installed. Check
for loose connections.
Lights are
turning on/off
repeatedly
• Ensure driver is not overloaded. An
overloaded driver will trip the internal
auto-reset (of driver) repeatedly,
turning the system on/off.
Mount channel to desired surface using minimum 2x M2.9 (#4)
screws or a similar size (not provided). Once channel is mounted,
firmly press HYDROLUME into channel pressing one end to the
other.
c
HYDROLUME Mounting Channel
INSTALLATION (CONT.)
4
5
6
ATTACH CONTROL AND DRIVER
Verify a compatible constant voltage driver is installed. Utilize
applicable wiring when installing outdoors.
REVIEW SYSTEM
Ensure all polarities are correct and connections are secured.
TURN POWER ON AT CIRCUIT BREAKER