background image

4 OF 8

IG022719-1.0

HYDROLUME

®

 SLIM 24V LED STRIP LIGHT

 

 INSTALLATION GUIDE

HYDROLUME

® 

SLIM 24V LED Strip Light

INSTALLATION GUIDE

INSTALLATION (CONT.)

Shift in 

brightness 

and/or kelvin

•  Ensure an appropriate gauge of 

wire is installed between strip light 

and LED driver. 

See VOLTAGE 

DROP CHARTS.

Some LEDs 

are not 

functional

•  Ensure strip light has not been bent 

excessively,  which  could  damage 

circuitry.

•  Ensure strip light has not been 

submerged in any liquid for any 

amount of time. 

Lights are 

flickering

•  Ensure a compatible driver and/or 

dimming control is installed. Check 

for loose connections.

Lights are 

turning on/off 

repeatedly

•  Ensure driver is not overloaded. An 

overloaded driver will trip the internal 

auto-reset  (of  driver)  repeatedly, 

turning the system on/off.

To Class 2 LED Driver,

GFCI, & Circuit Breaker

To Additonal

HYDROLUME

Pool / Spa

Junction Box

Corrosion

Resistant Conduit

4 in. Min.

48 in. Min.

J-Box to Edge of Pool

8 in. Min. 

Bottom of J-box

to Top of Water Line

Seal Conduit Entry with 

pool-grade silicone sealant

For  concrete  pools,  seal  conduit  entry  with  pool-grade 

silicone sealant. 

DO NOT drill holes in fiberglass pools/

hot tubs or vinyl-lined pools

. An alternate method is to 

route the wire directly out of pool.

4

5

6

ATTACH CONTROL AND DRIVER

Verify  a  compatible  constant  voltage  driver  is  installed.  Utilize 

applicable wiring when installing outdoors.

REVIEW SYSTEM

Ensure all polarities are correct and connections are secured.

TURN POWER ON AT CIRCUIT BREAKER

INSTALLATION: UL LISTED 676 MODELS

FOR UNDERWATER APPLICATIONS

3

CONT.

Summary of Contents for HYDROLUME SLIM 24V

Page 1: ...electrician 3 Do not modify or disassemble this product beyond instructions or the warranty will be void 4 Only install with a Listed Class 2 DC LED driver 5 Do not exceed maximum run recommended for...

Page 2: ...TOOLS 1 2 3 4 1 Appropriate Junction Box 2 Class 2 rated Driver 3 Compatible Dimmer or Switch 4 HYDROLUME SLIM LED Strip Light 5 HYDROLUME SLIM Mounting Brackets or Channels DO NOT BEND LED STRIP LIG...

Page 3: ...el to dry surface using a chlorine resistant waterproof adhesive Allow adhesive to cure dry NEC 680 When installing in water install in accordance with NEC 680 Per UL instructions It is required to mo...

Page 4: ...ded driver will trip the internal auto reset of driver repeatedly turning the system on off To Class 2 LED Driver GFCI Circuit Breaker To Additonal HYDROLUME Pool Spa Junction Box Corrosion Resistant...

Page 5: ...ation rated etc 3 MOUNT HYDROLUME TO SURFACE See mounting options a b c Mark placement for HYDROLUME Mounting Brackets roughly 12 inches apart Fasten brackets with M2 9 4 screw or similar size not pro...

Page 6: ...r dimming control is installed Check for loose connections Lights are turning on off repeatedly Ensure driver is not overloaded An overloaded driver will trip the internal auto reset of driver repeate...

Page 7: ...Output V Red Install appropriate wire gauge type V V LED Tape Light Fixture 8 REIGN 12 24V Dimmer4 V V L N AC Power 50 60Hz INPUT OUTPUT 1 Driver may not require a fault ground connection Refer to dri...

Page 8: ...1 7 A 50 W 2 1 A 60 W 2 5 A 70 W 2 9 A 80 W 3 3 A 100 W 4 2 A 18 AWG 134 ft 68 ft 45 ft 33 ft 27 ft 22 ft 19 ft 17 ft 14 ft 16 AWG 215 ft 109 ft 72 ft 54 ft 43 ft 36 ft 31 ft 27 ft 22 ft 14 AWG 345 ft...

Reviews: