26
L11
-
L21
1
st
LEVEL PEAK CURRENT I
1p
1806.M AC/DC
2506.M AC/DC
5 ÷ 220 A
5 ÷ 300 A
L19
2
nd
LEVEL PEAK CURRENT I
2p
1806.M AC/DC
2506.M AC/DC
5 ÷ 220 A
5 ÷ 300 A
L20
1
st
LEVEL BASE CURRENT I
1b
1806.M AC/DC
2506.M AC/DC
5 ÷ 220 A
5 ÷ 300 A
L23
PULSATION FREQUENCY f
1806.M AC/DC - 2506.M AC/DC
FAST
0,5 ÷ 500 Hz
To exit the setting phase, hold the WELDING PARAMETERS SE-
LECTION key (T10) down for about
1 second
.
3C - ULTRA FAST PULSE + SWITCH
Press the PULSE key (T5) until the requited
pulsation is active (ULTRA FAST LED flashing).
Press the WELDING MODE SELECTION key
(T9) until the SWITCH welding mode is active
(SWITCH LED on).
Press the WELDING PARAMETERS SELEC-
TION Key (T10) a number of times to set the following (in addi-
tion to the WELDING PARAMETERS defined as being “BASIC”):
L11 L19 L20
L21
L23
T10
L11
-
L21
1
st
LEVEL PEAK CURRENT I
1p
1806.M AC/DC
2506.M AC/DC
5 ÷ 220 A
5 ÷ 300 A
L19
2
nd
LEVEL PEAK CURRENT I
2p
1806.M AC/DC
2506.M AC/DC
25 ÷ 220 A
25 ÷ 300 A
L20
1
st
LEVEL BASE CURRENT I
1b
1806.M AC/DC
2506.M AC/DC
5 ÷ 220 A
5 ÷ 300 A
L23
PULSATION FREQUENCY f
1806.M AC/DC - 2506.M AC/DC
ULTRA FAST
500 ÷ 2000 Hz
To exit the setting phase, hold the WELDING PARAMETERS SE-
LECTION key (T10) down for about
1 second
.
PULSE
SYN
FAST
SLOW
T5
T9
3D - SYN PULSE + SWITCH
Press the PULSE key (T5) until the requited
pulsation is active (SYN LED on).
Press the WELDING MODE SELECTION key
(T9) until the SWITCH welding mode is active
(SWITCH LED on).
Press the WELDING PARAMETERS SELEC-
TION Key (T10) a number of times to set the
following (in addition to the WELDING PARAM-
ETERS defined as being “BASIC”):
L11 L19
L22
T10
L11
-
L21
1
st
LEVEL PEAK CURRENT I
1p
1806.M AC/DC
2506.M AC/DC
25 ÷ 220 A
25 ÷ 300 A
WARNING: When the SYN PULSE function is active, the 1
st
level
PEAK CURRENT ( I
1p
) is regulated to achieve a synergy with the
values for the other 1
st
level parameters ( I
1b
, f ).
L19
2
nd
LEVEL PEAK CURRENT I
2p
1806.M AC/DC
2506.M AC/DC
5 ÷ 220 A
5 ÷ 300 A
WARNING: When the SYN PULSE function is active, the 2
nd
level
PEAK CURRENT ( I
2p
) is regulated to achieve a synergy with the
values for the other 2
nd
level parameters ( I
2b
, f ).
If you want to do a test weld, during the test the LED for the pa-
rameter selected flashes and the DISPLAY shows the value for the
parameter you are setting.
To exit the setting phase, hold the WELDING PARAMETERS SE-
LECTION key (T10) down for about
1 second
.
NOTE: During the welding process if LED I
p
and LED I
1
stay
switched on on the DISPLAY, the 1
st
level current at which you
are welding is displayed.
NOTE: During the welding process if LED I
2
and LED I
p
stay
switched on on the DISPLAY, the 2
nd
level current at which you
are welding is displayed.
SPECIAL CONFIGURATION (SPE)
In welding processes:
•
TIG AC with HF ignition
•
TIG DC with HF ignition
The
Welding power source
makes it possible to activate modi-
fication of some WELDING PARAMETERS therefore providing a
more expert welder with a more versatile welding power source.
Activation will only take place after the welding power source con-
figuration is changed from STANDARD (Std) to SPECIAL (SPE),
which must be done as follows:
1) When the welding power source is off, push and hold the
“PRG” PROGRAM key down (T2).
2) Start the welding power source by turning the power supply
switch to position
I
.
PULSE
SYN
FAST
SLOW
T5
T9
Summary of Contents for DIX TIG GO 1806.M AC/DC
Page 10: ...10 Wiring diagram DIX TIG GO 1806 M AC DC...
Page 11: ...11 2101WA31...
Page 12: ...12 Wiring diagram DIX TIG GO 2506 M AC DC...
Page 13: ...13 2101WB09...