17
■
PULSE
When using one of the 3 TIG welding processes, it makes it pos-
sible to set one of the
4
pulsation modes available on the welding
power source, using the relevant button:
L27
SYN PULSE
L28
FAST PULSE
L28
ULTRA FAST PULSE
L29
SLOW PULSE
PULSE
SYN
FAST
SLOW
L27
L28
L29
L27
Synergic pulsations (SYN PULSE)
WARNING:
LED
L27
switched on and steady.
This can only be programmed when the TIG DC with HF ig-
nition or TIG DC with “Lift” type ignition welding processes
are used.
L28
Fast pulsations (FAST PULSE)
WARNING:
LED
L28
switched on and steady.
This can only be programmed when the TIG DC with HF ig-
nition or TIG DC with “Lift” type ignition welding processes
are used.
L28
Ultra fast pulsations (ULTRA FAST PULSE)
WARNING:
LED
L28
switched on and flashing.
Attivabile solo con i processi di saldatura TIG DC con innesco
HF o TIG DC con innesco tipo “Lift”.
L29
Slow pulsations (SLOW PULSE)
WARNING:
LED
L29
switched on and steady.
This can only be programmed when the 3 TIG welding pro-
cesses are used.
WARNING: The operator can decide to TIG weld without using
any pulsation mode. If this is the case, the 4 LEDs are switched off.
■
WELDING PARAMETERS
Each time the button is pushed, the welding power source selects
the next function according to the welding power source configu-
ration, the welding process, the welding mode, etc...
1A - STANDARD CONFIGURATION
ELECTRODE WELDING (MMA)
When using the electrode welding process, this allows you to select
the following welding parameters, based on which LED is flashing:
L9
HOT START
L10
ARC FORCE
L11
PRINCIPAL welding CURRENT I
1
L9
L10
L11
1B - STANDARD CONFIGURATION
TIG WELDING
When one of the
3
TIG welding processes available on the weld-
ing power source is activated, this allows you to select the follow-
ing welding parameters, based on which LED is flashing:
L12
PRE-GAS duration
L13
SLOPE UP duration
L14
BASE current duration T
b
WARNING: This can only be programmed when SLOW pulsa-
tion is activated.
L15
PEAK current duration T
p
WARNING: This can only be programmed when SLOW pulsa-
tion is activated.
L16
SLOPE DOWN duration
L17
POST-GAS duration
L18
INITIAL welding CURRENT
L11
PRINCIPAL welding CURRENT I
1
L19
SWITCH CURRENT I
2
WARNING: This can only be programmed when the SWITCH
welding mode is active.
L20
BASE CURRENT I
b
WARNING: This can only be programmed when at lease one pul-
sation mode is activated.
L21
PEAK CURRENT I
p
WARNING: This can only be programmed when at least one pul-
sation mode is activated.
L22
FINAL welding CURRENT
L23
PULSATION FREQUENCY f
WARNING: NOT programmable when SLOW pulsation mode is
active.
L18 L11 L19 L20
L21 L22
L17
L16
L15
L23
L14
L13
L12
2 -
SPECIAL CONFIGURATION
TIG WELDING (only for expert welders)
For this configuration, in addition to the parameters already de-
fined for the STANDARD configuration, you can also set the fol-
lowing parameters:
L9
IGNITION CURRENT
WARNING: This can only be programmed when the TIG AC with
HF ignition or TIG DC with HF ignition welding processes are
used.
L9
IGNITION TIME duration
WARNING: Only programmable when the TIG AC with HF igni-
tion welding process is activated.
L18
INITIAL welding CURRENT
WARNING: This can only be programmed when the TIG AC with
HF ignition or TIG DC with HF ignition welding processes and
the 2 STROKES welding mode are used.
L22
FINAL welding CURRENT
WARNING: This can only be programmed when the TIG AC with
HF ignition or TIG DC with HF ignition welding processes and
the 2 STROKES welding mode are used.
L9
L18
L22
WARNING: This special parameter is only to be activated by
qualified personnel, or those trained by technicians.