Operator’s Manual
Maintenance
GTWY1200 SERIES 9
Observe and Obey:
Only routine maintenance items specified in
this manual shall be performed by the
operator.
Scheduled maintenance inspections shall be
completed by qualified service technicians,
according to the manufacturer's specifications
and the requirements specified in the
responsibilities manual.
Maintenance Symbols Legend
The following symbols have
been used in this manual to help communicate
the intent of the instructions. When one or
more of the symbols appear at the beginning
of a maintenance procedure, it conveys the
meaning below.
Indicates that tools will be required to
perform this procedure.
Indicates that new parts will be
required to perform this procedure.
Check the Battery - DC Models
Proper battery condition is essential
to good machine performance and
safe operation. Improper fluid levels
or damaged cables and connections can result
in component damage and hazardous
conditions.
Electrocution hazard. Contact
with hot or live circuits could result in death or
serious injury. Remove all rings, watches and
other jewelry.
Bodily injury hazard.
Batteries contain acid. Avoid spilling or
contacting battery acid. Neutralize battery acid
spills with baking soda and water.
Perform this test after fully
charging the battery. 1 Put on protective
clothing and eye wear.
2 Remove the battery vent caps.
3 Check the battery acid level. If needed,
replenish with distilled water to the bottom of
the battery fill tube. Do not overfill.
4 Install the vent caps.