www.dimplex.de
E-9
English
12
12 Device information
1
Type and order code
WI 50TU
WI 100TU
2
Design
2.1
Model / controller
Universal / internal
Universal / internal
2.2
Thermal energy meter
Integrated
Integrated
2.3
Installation location / degree of protection according to EN 60 529
Indoor / IP 21
Indoor / IP 21
2.4
Water in device protected against freezing
1
1. The heat circulating pump and the heat pump controller must always be ready for operation.
Yes
Yes
2.5
Performance levels
2
2
3
Operating limits
3.1
Heating water flow / return
°C
up to 58 ± 2
up to 58 ± 2
3.2
Cold water (heat source)
°C
+7 to+25
+7 to+25
4
Performance data / flow rate
4.1
Heating water flow rate with an internal pressure differential of
W10 / W35/30
m³/h / Pa
16.5 / 17700
W10 / W45/38
m³/h / Pa
11.3 / 9100
Minimum heating water flow rate
W10 / W55/45
m³/h / Pa
7.5 / 4500
4.2
Cold water flow rate at an interal pressure differential of
2
W10/7 W35
m³/h / Pa
2. The given well water flow rate is identical for all operating points.
21.2 / 21700
4.3
Heat output / COP
3
3. These data indicate the size and capacity of the system according to EN 255 / EN14511. For an analysis of the economic and energy efficiency of the system, the bivalence point
and regulation should be taken into consideration. The specified values, e.g. W10/W55, have the following meaning: Heat source temperature 10 °C and heating water flow tem-
perature 55°C.
10K
5K
4
10K
5K
4
4. The temperature spread of 5K is based on the standard value of W10 / W35 in operation with 2 compressors.
at W10 / W55
kW / ---
5
5. Operation with 2 compressors.
43,3 / 3,5
86,7 / 3,3
kW / ---
6
6. Operation with 1 compressor.
22,2 / 3,6
40,2 / 3,0
at W10 / W45
kW / ---
5
45,5 / 4,5
90,9 / 4,1
kW / ---
6
23,7 / 4,6
47,6 / 4,3
at W10 / W35
kW / ---
5
49,0 / 6,1
47,3 / 5,7
98,5 / 5,6
95,5 / 5,3
kW / ---
6
26,3 / 6,3
25,1 / 5,9
52,8 / 6,1
51,7 / 5,8
4.4
Sound power level
dB(A)
59
70
4.5
Sound pressure level at a distance of 1m
7
dB(A)
7. The specified sound pressure level corresponds to the operating noise of the heat pump in heating operation with a flow temperature of 35°C. The specified sound pressure level
represents the free sound area level. The measured value can deviate by up to 16 dB(A), depending on the installation location.
44
56
5
Dimensions; weight and filling quantities
5.1
Device dimensions without connections
8
H x Wx L mm
8. Please note that additional space is required for pipe connections, operation and maintenance.
1660 x 1000 x 775
1890 x 1350 x 775
5.2
Device connections for heating
Inches
R 1 1/2“ Int. Thread
R 2“ Int. Thread
5.3
Device connections for heat source
Inches
R 2“ Int. Thread
R 2 1/2“ Int. Thread
5.4
Weight of the transportable unit(s) incl. packaging
kg
373
593
5.5
Refrigerant; total filling weight0
Type / kg
R404A / 7,5
R404A / 15,8
5.6
Lubricant; total filling quantity
Type / litres
Polyolester (POE) / 3,8
Polyolester (POE) / 6.5
6
Electrical connection
6.1
Load voltage; Fuse protection
3~/PE 400V (50Hz) / 32AT
3~/PE 400V (50Hz) / 36AT
6.2
Control voltage; Fuse protection
1~/N/PE 230V (50Hz) / 13A
1~/N/PE 230V (50Hz) / 13A
6.3
Starting current with soft starter
A
29
100
6.4
Nominal power consumption W10 / W35 / max. consumption
3
kW
8,3 / 12,8
18,0 / 28,4
6.5
Nominal current W10/W35 / cos
ϕ
A / ---
14,9 / 0,8
33,4 / 0,8
6.6
Power consumption of compressor protection
(per compressor)
W
70; thermostat controlled
70; thermostat controlled
7
Complies with the European safety regulations
9
9. See CE certificate of conformity.