21
NOTE:
It is important that if multiple heaters are installed in one room that all heaters have the Adaptive Start
(AS) function enabled. If this is not the case, heaters with AS enabled will pre-heat the room to the
desired target temperature before the heaters with AS disabled attempt to output heat.
It is likely that if two heaters are required in one room, that the output from one heater may not be
suffi
cient to heat the room alone. This may cause the pre-heat time calculation to extend to a large
degree if the heaters do not all have AS enabled. This may lead to heat
at unwanted times and excessive wear to some heaters.
A two-hour limit is enforced on the calculation, however, if all heaters have AS enabled and pre-
heating takes over one-hour, extreme environmental factors may be aff ecting the calculation or the
heaters may be under sized for the room. Please contact us for support
if your pre-heat time seems excessive.
NOTE:
This is a continuously learning function and will be aff ected daily by changes in the heater’s
environment. The heater will take into account the starting temperature of the room so pre-heating
should remain accurate.
Adaptive Start Setting
Adaptive Start is predictive function that only modifi es Timer Mode operation. This function models the heating
characteristics of the room and uses that information to pre-heat the room for only the time required to achieve
the
Target Temperature
by the start of the
Heating On
period.
For example, with Adaptive Start off , the
Heating On
time is the time that the Heater will begin to try and achieve
the
Target Temperature
. With
Adaptive Start
On, the Heater will begin to heat the room before the User-defi ned
Heating On
time so that the
Target Temperature
is achieved when the User defi ned the
Heating On
start time.