www.glendimplex.de
452172.66.01-EN · FD 0204
EN-7
LIA 0608HWCF M - LIA 0911HWCF M English
4
Transport and storage
During transport and storage, the unit must be kept in a dry
place and must not be exposed to temperatures below freez-
ing.
When storing the device, care should be taken to ensure that no
other gases, liquids or solids can enter the device. The connec-
tions of the device should remain closed until the device is fi-
nally installed. Furthermore, care must be taken to ensure that
no damage can occur to the device or individual components
during the transport and storage of the device. Please make
sure that the device is not stacked (no load from above on the
device) or crushed.
When storing the device, make sure that it is stored in a room
with a sufficiently large space (especially when storing in base-
ments, garages, conservatories, etc.).
CAUTION!
!!
Refer to the product packaging labels for storage and
transport information.
CAUTION!
!!
The device must be stored in a well ventilated room where
there is no continuously present ignition source (example:
naked flames, gas-powered household appliance, electrically-
powered heating device, workshops).
CAUTION!
!!
The device must be stored in a well ventilated room where the
room size corresponds to the intended room area for
operation. (see cap. 5.3.4)
A pallet should be used for transportation to the final installa-
tion location.
Due to the high tare weight of the indoor unit, it should be
transported by means of a lift truck, hand truck, or similar. If this
is not possible, always transport the unit with several people.
When transporting the device, care must be taken not to dam-
age the unit, components and connections. Also protect the
device from moisture during transport.
The indoor unit tends to tip over when unfilled. Make sure that
it stands safely. If possible, the unit should always be trans-
ported upright.
CAUTION!
!!
The indoor unit and transport pallet are connected together
with screws.
NOTE
ººººº
The indoor unit must not be tilted by more than 45°.