www.glendimplex.de
452172.66.01-EN · FD 0204
EN-29
LIA 0608HWCF M - LIA 0911HWCF M English
13 Device information
1
Type and order code
LIA 0608HWCF M
LIA 0911HWCF M
2
Design
Heat source
Air
Air
2.1
Version
Split
Split
2.2
Controller
WPM Touch
WPM Touch
2.3
Thermal energy metering
--
--
2.4
Installation location
Indoors/outdoors
Indoors/outdoors
2.5
Performance level
Variable
Variable
3
Operating limits
3.1
Heating water flow/return
° C
up to 65 / from 12
up to 65 / from 12
3.2
Cooling water flow
° C
7 to 25
7 to 25
3.3
Air (heating)
° C
-25 to +35
-25 to +35
3.4
Air (cooling)
° C
-5 to +43
-5 to +43
4
Flow/sound
4.1
Heating water flow / internal pressure differential
Nominal flow according to EN 14511
m³/h
0.75
1.47
Minimum heating water flow rate
-
-
-
4.2
Sound power level outside
Normal operation A7/W55 EN12102
dB(A)
58
60
4.3
Sound power level lowered operation
dB(A)
53
55
4.4
Sound power level inside
dB(A)
42
42
5
Dimensions, weight and filling quantities
5.1
Device dimensions
1
indoor unit H x W x D mm
Outdoor unit
H x W x D mm
1880 x 595 x 600
712 x 1008 x 426
1880 x 595 x 600
865 x 1118 x 523
5.2
Weight outdoor unit / incl. packing
kg
60 / 65.5
78.5 / 92
5.3
Device connections for heating
Inches
3/4
3/4
5.4
Device connections for domestic hot water
Inches
3/4
3/4
5.5
Refrigerant/total filling weight
Type/kg
R32 / 1.5
R32 / 1.65
5.6
GWP value / CO
2
equivalent
--- / t
675 / 1.01
675 / 1.2
5.7
Lubricant Type
Synthetic oil
Synthetic oil
5.8
Maximum operating pressure
bar
3
3
5.9
Domestic hot water cylinder
Volume
litres
193
193
Heat exchanger area
m²
2.0
2.0
Permissible operating temperature °C
75
75
Permissible operating pressure
bar
10
10
5.10 Electrical pipe heater
6
6
5.11 Start-to-leak pressure, safety valve
bar
3
3
6
Electrical connection
6.1
Supply voltage / fusing / RCD type
Outdoor unit
1~/N/PE 230 V (50 Hz) / C20A
1~/N/PE 230 V (50 Hz) / C20A
Indoor unit
with 230 V connection
1~/N/PE 230 V (50 Hz) / B32A
1~/N/PE 230 V (50 Hz) / B32A
with 400 V connection
3~/N/PE 230 V (50 Hz) / B16A
3~/N/PE 230 V (50 Hz) / B16A
RCD type
B
B
6.2
Control voltage / fuse protection
1~/N/PE 230 V (50 Hz) / B13A
1~/N/PE 230 V (50 Hz) / B13A
6.3
Degree of protection according to EN 60 529 Inside 7
IP X4
IP X4
6.4
Starting current limiter
Inverter
Inverter
6.5
Rotary field monitoring
Yes
Yes
6.6
Starting current
A
5
5
6.7
Nominal power consumption at A7/ W35 (EN14511)
kW
1.24
2.00
6.8
Nominal current at A7/W35
A
5.4
8.7
6.9
Nominal power consumption at A2/ W35 (EN14511)
kW
1.26
2.02
6.10 Power consumption of compressor protection (per compressor)
W
--
--
6.11 Power consumption of fan
W
100
100
7
Complies with the European safety regulations
See CE declaration of conformity