background image

Installation

The Fixing Kit should contain: 1 Drilling Template, 3 Screws, 3
Rawlplugs, 1 Mounting Bracket and 1 Hexagon Key.

Wall Mounted Operation  

(see 

Fig. 2

)

Suggested Fixings

SOLID BRICK/BLOCK:  

No. 8 Rawlplug inserts, 6mm drill bit.

PLASTERBOARD: 

 If possible locate studding and use No. 8

woodscrews directly into the wood, otherwise M5 rawlplug
intersets are suitable.

NOTE: FOR OTHER WALL TYPES 

(e.g. Timber frame and hollow

concrete) 

SEEK SPECIALIST ADVICE.

1. Select the position for the heater ensuring there is

clearance from any furniture and fittings of at least 150mm
above the heater, 50mm below and 25mm each side.

Curtains must not be closer than 150mm from the top of
theheater.

2. Position the drilling template provided on the wall ensuring

it is level.  Mark the position of the relevant holes on the
wall  at the edge of template.  Before drilling check that the
distance between the hole centres is correct, 340mm for
400W Models and 540mm for 800W models (see 

Fig.  2

).

130mm

340mm - 400W
540mm - 800W

95mm

150mm

50mm

420mm

25mm

25mm

130mm

Drilling Holes

Bracket

Fig. 2

Positioning the Heater

Select the position for the heater ensuring there is clearance
from any furniture and fittings of at least 150mm above the heater,
50mm below (wall mounted) and 25mm each side.  Curtains
must not be closer than 150mm from the top of the heater.

Free Standing Operation 

(see 

Fig. 1

)

NEVER USE THE HEATER FREE STANDING WITHOUT THE FEET
FITTED 

(FEET ARE PACKED SEPARATELY IN CARTON).

1. Lay the heater on its front.
2. Remove the two socket head screws from the base of

the heater using the hexagon key supplied.

3. Place feet over base of heater, align holes and engage

hook on foot into the recess on the back of the heater -
see 

Fig. 1

.

4. Replace the screws but do not overtighten.

Fig. 1

Rear View

3. Drill the wall at the three marked positions and fit the wall

plugs.

Ensure template has been removed.

4. Fix two No. 8 screws to the top two holes leaving 3mm of

the screw exposed.  Hang the heater on the screws.

5. Fit the bottom bracket, found in the fixing kit, in the slot at

the base of the heater and screw the bracket to the wall.

Test that the heater is now securely fixed to the wall.

Operation

IMPORTANT - OBJECTS OR CLOTHING MUST NOT BE PLACED
ON THIS HEATER.
Before using the heater ensure that all warnings and
instructions have been read carefully.

OPERATION - SINGLE RATED MODELS

Models DXLWP400, DXLWP400TI, DXLWP800, and
DXLWP800TI N
Turn the heater on using the switch on the right side of the heater
- the switch will be illuminated.

OPERATION - DUAL RATED MODEL - Model ARLWP800TI

The two switches on the side of the heater control the heat output.
Both switches illuminated indicates maximum output.

Top switch only

 illuminated indicates 500W output on 800W

model.

Bottom switch only

 illuminated indicates 300W output on 800W

model.
Note: on models fitted with a timer, at least one switch must be
illuminated for the heater to operate.

MODELS WITH TIMER -

 (see

 Fig. 3

)

DXLWP400TI and DXLWP800TI N -  1 Switch

,

The switch on the side of the heater turns the heater on.
Note: This switch must be in the “on” position before the heater
will operate.

ARLWP800TI - 2 Switches

The two switches on the side of the heater control the amount of
heat available as described above, (Operation - Dual Rated
Model).
NOTE: At least one switch must be in the ‘On’ position before the
heater will operate.

Summary of Contents for ARLWP800TI

Page 1: ...ntroller timer or any other device which switches the heater on automatically observe all safety warnings at all times 600 mm 400W 800 mm 800W 500 mm Important Safety Advice WARNING THIS APPLIANCE MUST NOT BE USED IN A BATHROOM WARNING DONOTUSETHISHEATERINTHEIMMEDIATE SURROUNDINGSOFABATH ASHOWERORASWIMMING POOL WARNING THIS HEATER MUST NOT BE LOCATED IMMEDIATELYBELOWAFIXEDSOCKETOUTLET The plug mus...

Page 2: ...on key supplied 3 Place feet over base of heater align holes and engage hook on foot into the recess on the back of the heater see Fig 1 4 Replace the screws but do not overtighten Fig 1 Rear View 3 Drill the wall at the three marked positions and fit the wall plugs Ensure template has been removed 4 Fix two No 8 screws to the top two holes leaving 3mm of the screw exposed Hang the heater on the s...

Page 3: ...mes you don t require heat see Fig 4 Each segment pushed in switches the heater OFF for that part of the hour All other segments will be ON For example Fig 5 shows the timer set to switch the heater ON between 7 am and 9 am and between 4 pm and 9 30 pm 2 You can select as many ON periods as you like within the 24 hour day The settings will repeat every day until changed 3 To change ON and OFF time...

Page 4: ...ire after sales service you should contact our customer services help desk on 0870 727 0101 It would assist us if you can quote the model number series date of purchase and nature of the fault at the time of your call The customer services help desk will also be able to advise you should you need to purchase any spares Please do not return a faulty product to us in the first instance as this may r...

Reviews: