background image

Dimplex Low Wattage Panel Heaters
Models: DXLWP400, DXLWP400TI,

DXLWP800, DXLWP800TI N & ARLWP800TI

Installation and Operating Instructions

Dimensions

(millimetres)

Models

Specification

DXLWP400

400W   Neon Heat Switch

DXLWP400TI

400W   Neon Heat Switch / 24 Hour Timer

DXLWP800

800W   Neon Heat Switch

DXLWP800TI N

800W   Neon Heat Switch / 24 Hour Timer

ARLWP800TI

800W   2 Neon Heat Switches / 24 Hour Timer

THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE

Electrical Connection

WARNING THIS APPLIANCE MUST BE EARTHED

If the socket outlets in your home are not of the 13 amp BS1363
type they will not accept the plug connected to this heater, therefore
cut off the plug.  When cut off this plug can constitute a shock
hazard if inserted into a socket outlet.  It must therefore be
disposed of safely.
Before wiring the appropriate plug please note that the wires in
this mains lead are coloured in accordance with the following
code.

GREEN/YELLOW:

EARTH

BLUE:

NEUTRAL

BROWN:

LIVE

Connect the 

Green/Yellow

 wire to the terminal marked 

E

 or the

earth symbol 

 or coloured 

Green

 or 

Green/Yellow

.

Connect the 

Brown

 wire to the terminal marked 

L

 or coloured

Red

.

Connect the 

Blue

 wire to the terminal marked 

N

 or coloured

Black

.

DO NOT 

connect the 

Brown

 (

Live

) or the 

Blue

 (

Neutral

) wires to

the 

Earth

 terminal of your 13 amp plug.  If the terminals of the

plug are unmarked or you are in any doubt, consult a qualified
electrician.

CAUTION: 

If you use this heater in conjunction with a thermal

control, programme controller, timer or any other device which
switches the heater on automatically observe all safety warnings
at all times.

600 mm - 400W

800 mm - 800W

500 mm

Important Safety Advice

WARNING –THIS APPLIANCE MUST NOT BE USED IN A
BATHROOM.

WARNING  - DO NOT USE THIS HEATER IN THE IMMEDIATE

SURROUNDINGS OF A BATH, A SHOWER OR A SWIMMING
POOL.

WARNING – THIS HEATER MUST NOT BE LOCATED
IMMEDIATELY BELOW A FIXED SOCKET OUTLET.

The plug must be accessible after heater installation.

DO NOT USE THE HEATER UNTIL THE FEET OR WALL
BRACKETS ARE FITTED CORRECTLY.

FOLLOW these instructions carefully.

The heater carries a warning ‘DO NOT COVER’ to alert the
user to the risk of fire that exists if the heater is
accidentally covered.

Models DXLWP400TI, DXLWP800TIN and ARLWP800TI
can be set to switch on automatically.  Remember to
observe all safety warnings at all times.

This appliance is not intended for use by children or other
persons without assistance or supervision if their
physical, sensory or mental capabilities prevent them
from using it safely. Children should be supervised to
ensure that they do not play with the appliance.

If young children, the aged or infirm are likely to be left in
the vicinity of the heater, we advise that adequate
precautions should be taken.  We recommend a guard
be fitted to ensure contact with the heater is avoided and
objects cannot be inserted into the product.

If the mains lead is damaged, it must be replaced by the
manufacturer or its service agent or a similarly qualified
person in order to avoid a  hazard.

For further information, please contact our guard supplier
direct on Tel. No. 01603 667957, or in case of difficulty or
for further advice contact the Customer Helpline.

INDUKLWPRG      Issue 6

Summary of Contents for ARLWP800TI

Page 1: ...ntroller timer or any other device which switches the heater on automatically observe all safety warnings at all times 600 mm 400W 800 mm 800W 500 mm Important Safety Advice WARNING THIS APPLIANCE MUST NOT BE USED IN A BATHROOM WARNING DONOTUSETHISHEATERINTHEIMMEDIATE SURROUNDINGSOFABATH ASHOWERORASWIMMING POOL WARNING THIS HEATER MUST NOT BE LOCATED IMMEDIATELYBELOWAFIXEDSOCKETOUTLET The plug mus...

Page 2: ...on key supplied 3 Place feet over base of heater align holes and engage hook on foot into the recess on the back of the heater see Fig 1 4 Replace the screws but do not overtighten Fig 1 Rear View 3 Drill the wall at the three marked positions and fit the wall plugs Ensure template has been removed 4 Fix two No 8 screws to the top two holes leaving 3mm of the screw exposed Hang the heater on the s...

Page 3: ...mes you don t require heat see Fig 4 Each segment pushed in switches the heater OFF for that part of the hour All other segments will be ON For example Fig 5 shows the timer set to switch the heater ON between 7 am and 9 am and between 4 pm and 9 30 pm 2 You can select as many ON periods as you like within the 24 hour day The settings will repeat every day until changed 3 To change ON and OFF time...

Page 4: ...ire after sales service you should contact our customer services help desk on 0870 727 0101 It would assist us if you can quote the model number series date of purchase and nature of the fault at the time of your call The customer services help desk will also be able to advise you should you need to purchase any spares Please do not return a faulty product to us in the first instance as this may r...

Reviews: