Heater Installation
is preferred but not essential in
all cases. A dedicated circuit will
be required if, after installation,
the circuit breaker trips or fuse
blows on a regular basis when the
heater is operating. Additional ap-
pliances on the same circuit may
exceed the current rating of the
circuit breaker.
Installation Options
The heater is supplied installed
in a Dimplex mantel. The heater
is intended to be plugged into
the Dimplex Optimyst
®
Cassette
which will allow the unit to be con-
trolled using the provided remote
to provide supplemental heat.
If not installing the unit into a Dim-
plex mantel the
required open-
ing dimensions
of the heater
are: 12.6 in. (320 mm) wide x
3.5 in. (89 mm) high x 7.7 in.
(196 mm) deep.
!
NOTE:
The heater does not
require any additional venting.
!
NOTE:
If installing the unit in
a custom built mantel install
the heater so that the pilot light
can be seen 5 ft (153 cm) from
the floor and 10 ft (305 cm)
from the unit. (Figure 2)
Wiring
12.4 in.
(315 mm)
15.0 in.
(380 mm)
3.3 in.
(84 mm)
7.7 in.
(196 mm)
Figure 3 - Unit Dimensions