30
VISUAL INDICATORS
The system has been planned to provide for visual
indications about the operation status in normal or
anomalous conditions.
BLINKING LAMP.
Blinking lamp off:
•
The door is closed: the system is waiting for a
remote control device opening signal or a key
contact opening signal.
•
The door is open: the system is waiting for a remote
control device closing signal or a key contact signal
(manual program selected by means of switch 3 on
OFF)
The blinking lamp is rapidly blinking: the gate is opening.
The blinking lamp is normally blinking: the gate is closing.
The blinking lamp is slowly blinking: the gate is on
pause and the AUTOMATIC CLOSING has been setup.
The blinking lamp turns on for five seconds as soon as
it receives the signal and then it turns off: the system
tried to close the gate but the infrared system contact
was not closed.
The blinking lamp turns on by means of a START
command without any door movement:
when the key 1 or 2 of one of the recorded transmitters
is pressed or a key contact is used and the blinking
lamp is on during all the transmission/contact closing
time, means that the control unit detects an open
contact to the STOP terminals.
Since the STOP button is optional, if it has not been
installed, it could be the case that the jumper on the
STOP terminals is instable; then, it will be necessar y to
check it and repair or replace it, if necessar y.
The blinking lamp is blinking permanently:
this may be caused by a defect during the door opening
or closing phase, a wild wind that does not allow any
door movement, for instance.
To restore the situation: act on the key contact and
press the remote control device button at the same
time, then the normal cycle will star t again.
WARNING!
The remote control device button and the key correctly
turned shall be kept pressed during all the closing or
opening time.
The resulting movement is “one door at a time” and as
soon as the user realizes that the first door stroke is
finished, he shall immediately release remote control
device button and key. The blinking lamp will always be
blinking to show that the same operation shall be car-
ried out on the other door.
LED ON THE CONTROL UNIT
On the control unit there are two LED luminous
indicators, which the silk screen-printing shows as L1
and L2.
As for L1, the indications it provides for have been
already examined in the program phase.
L2 is used to show the charge status of the unit
connected accumulator.
LED ON: the accumulator is on charge
LED OFF: the accumulator is charged