19
The P2 parameter is a setting mode for wheel speed pulse signal. If wheel generated
1 pulse signal by a revolution, the P2 value should be set to 1. If the wheel generated
6 pulse signals by a revolution, P2 should be set as 6. If users did not configure the
parameter then P2 can be set to 0. The selection of P2 values ranges from 0 to 6.
P3 Power Assist Control Setting
The P3 parameter setting will display on the meter after the P2 parameter setting has
been selected and confirmed. The KT-LCD3 will display as follows:
P3 parameters affect the power assist control setting. When the value is set to 0, the
throttle is dependent on the PAS Gear Ratio. This means when the PAS gear ratio is 1,
the throttle will provide the least amount of power, whereas when it is 5, the throttle
will provide the most power. If the P3 parameter is set to 1, the throttle will provide the
maximum power regardless on the PAS gear ratio chosen.
P3 Display
P4 Throttle Start-Up Setting
The P4 parameter setting will display on the meter after the P3 parameter setting has
been selected and confirmed. The KT-LCD3 will display as follows:
P4 Display