Chapter 2: Unit Installation
Hardware Installation
This section describes how to properly install the hardware for a Gateway
Series appliance.
Caution
Only qualified service personnel should continue with
hardware installation and configuration of the Gateway Series
appliance. Users should not attempt to perform these functions
themselves.
Caution
This equipment is intended for use in Restricted Access Areas
only where equipotential bonding has been applied.
Grounding
The Gateway Series appliance must be properly earth grounded for safety
reasons. If the unit is not properly earth grounded, the unit and/or other
equipment connected to the unit could be damaged. If a Gateway Series
appliance is damaged while it is improperly grounded, the warranty on
the Gateway Series appliance is void.
A ground lug is located on the opposite side from the front panel of a
Gateway Series appliance. Attach an appropriate length and gauge of wire
to the double-crimp ground ring terminal. The wire length should be as
short as possible, and gauge should be 18 AWG or greater. Stranded or
solid wire is acceptable. Wire is not provided with the Gateway Series
Digium, Inc.
Page 24